circuitry. Disconnect power supply before installation. RESISTANCE (OHMS) Location Locate the remote sensor about 5 ft (1.5m) above the floor on an inside wall where it will be affected by freely circulating air at average room temperatures. Mounting 1. Loosen the cover locking screw with the Allen wrench provided and remove the device cover. 2. Run wire to the selected location. 3. Thread wire through the semicircular hole in the 2000 1800 1600 1400 1420 OHMS AT 75 F (24 C) 1200 1000 F 10 20 30

Téléchargements : 4   Taille : 145 kb   Fabricant : Honeywell  
Catégorie : Autres outils
@name

Its primary use is with the T7300 Programmable Commercial Thermostat (only in return air) to control heating or cooling equipment. NOTE: The T7022 can also be used with a T7100F, provided the proper Q7100 subbase—one capable of handling more than one stage of heat—is used. IMPORTANT All wiring must agree with applicable codes, ordinances and regulations. Wiring (Fig. 1) Wiring for the T7022 Remote Temperature Sensor can be run with class 2 wire in accordance with the National Electrical Cod

Téléchargements : 1   Taille : 334 kb   Fabricant : Honeywell  
Catégorie : Autres outils
@name

63-2150—5 2 C7600A SOLID STATE HUNIDITY SENSOR 20 18 16 14 12 10 8 6 4 0 CURRENT IN mA HUMIDITY IN % RH M3130 Fig. 2. C7600A output current vs. relative humidity. INSTALLATION When Installing this Product… 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. Checkout

Téléchargements : 6   Taille : 3 mb   Fabricant : Honeywell  
Catégorie : Autres outils
@name

The options for this menu item are: • “SIGNAL > SETPOINT” means the limit will activate when the signal is higher than the set point. • “SIGNAL < SETPOINT” means the limit will activate when the signal is lower than the set point. • “SIGNAL INSIDE” means the limit will activate when the signal is in between the set point and the return point. • “SIGNAL OUTSIDE” means the limit will activate when the signal is not in between the set point and the return point. The figures below further illustrate

Téléchargements : 3   Taille : 3 mb   Fabricant : Honeywell  
Catégorie : Autres outils
@name

page 108 008-0608-00 Each High-Level Input channel is configured and calibrated via its channel menu. Detailed instructions on operating the instrument in the SETUP Menu mode can be found in “SETUP Menu mode” on page 23. A diagram of all menus is located in “Setup Menu Reference” on page 157. 12.6.1 OPERATION Sub-Menu This menu controls the operation of this channel when the instrument is in the RUN mode. AUTO-ZERO Menu Item This enables or disables the channel’s automatic zeroing function. The

Téléchargements : 55   Taille : 3 mb   Fabricant : Honeywell  
Catégorie : Autres outils
@name

CAUTION Only qualified, service-trained personnel who are aware of the hazards involved should remove the cover from the instrument or connect external wiring to the instrument. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. Contents Contents Contents . . . . . . . . . . . . . . . . . .

Téléchargements : 14   Taille : 232 kb   Fabricant : Honeywell  
Catégorie : Autres outils
@name

T7147 Remote Sensor and Override Module PRODUCT DATA FEATURES • Locking cover. • Override key. • Warmer/Cooler keys on some models. • Key-lock override security available. Contents Application ........................................................................ 1 Features ........................................................................... 1 Specifications ................................................................... 2 Ordering Information .......................................

Téléchargements : 10   Taille : 197 kb   Fabricant : Honeywell  
Catégorie : Autres outils
@name

14. Two T7047G1000 Sensors providing a temperature-averaging network for a T7300/Q7300 Thermostat/Subbase. Q7300 T T M3422 T T T7047GT T T7047G T T T7047G T T T7047G T T T7047G Fig. 15. Five T7047G1000 Sensors providing a temperature-averaging network for a T7300/Q7300 Thermostat/Subbase. Q7300 T T M3419 T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C Fig. 16. Nine T7047C1025 Sensors providing a temperature-averaging network for a T7300/Q7300 Th

Téléchargements : 6   Taille : 197 kb   Fabricant : Honeywell  
Catégorie : Autres outils
@name

SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. This product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. Models: T7047C: 2-wire remote sensor with no internal adjustment means (requires remote setpoint device such as S963B, T7067B, and T7080B). T7047C

Téléchargements : 4   Taille : 725 kb   Fabricant : Honeywell  
Catégorie : Autres outils
@name

The C7400S communicates temperature and humidity separately digitally on the Sylk Bus Communication Protocol. A separate controller such as the JADE™ Economizer System (Model W7220) provides power and communications on the Sylk Bus for the C7400S Sylk Bus sensor. SPECIFICATIONS Electrical Supply Voltage: 7 to 21 Vdc Power Consumption: 5 mA Output Rating: 75 ohm load switched at 9600 Baud Wiring: Sylk Bus: 2-wire (18 to 22 AWG) Environmental Operating Temperature range: -40 to 150 °F (-40 to 65 °