Replace the PWB Assembly. Repair drain hose Remove foreign material. Reconnect or repair the connector Replace the pump assembly Replace the PWB Checking voltage between two pins as press the power button is the voltage 220-240V~? Is the drain hose twisted or frozen? Is the impeller of the drain pump clogged? Is the connector disconnected, disassembled? Is the coil of drain pump cut-off? (resistance of coil is 90~160.) When checking voltage between connectors ( , )on spinning, is the voltage 220 - 240V~ as the figure? When pressing [Spin] and [Temp.] at the same time after draining, is the water level frequency 252 or more? When pressing [Spin] [Temp.] buttons at the same time while wash, is the water level frequency between 230 - 245V~? HEATING WITHOUT WATER DRAIN MALFUNCTIONING NO NO YES YES YES NO NO NO NO YES YES NO PWB ASSEMBLY PWB ASSEMBLY 1 2 Replace the sensor (pressure). Replace the PWB Assembly. Repair drain hose Remove foreign material. Reconnect or repair the connector Replace the pump assembly Replace the PWB Checking voltage between two pins as press the power button is the voltage 220-240V~? Is the drain hose twisted or frozen? Is the impeller of the drain pump clogged? Is the connector disconnected, disassembled? Is the coil of drain pump cut-off? (resistance of coil is 90~160.) When checking voltage between connectors ( , )on spinning, is the voltage 220 - 240V~ as the figure? When pressing [Spin] and [Temp.] at the same time after draining, is the water level frequency 252 or more? When pressing [Spin] [Temp.] buttons at the same time while wash, is the water level frequency between 230 - 245V~? HEATING WITHOUT WATER DRAIN MALFUNCTIONING 21 22 AC 220-240V (1) 1 6 Replace the thermistor Push the thermistor tightly to the rubber. When disconnecting the connector (1) on the PWB assembly (Main) is the resistance of the Natural connectors [..(Blue White), ..(White)] between 2.5k. to 180k.(105°C~0°C)? When checking thermistor on the tub, is the thermistor loosened above 2mm from the rubber? HEATING CONTINUOUSLY ABOVE THE SETTING WATER TEMPERATURE 23 NO YES YES YES NO NO NO YES 1 10 5 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 SPIN TROUBLE Check the sensor (Pressure) or hose (Sensor). If the problem is on the sensor or the hose, replace the sensor or the hose. Normal Reconnect or repair it. Replace the motor assembly. Press [Power] button with [Temp] and [Option] buttons pressed after power off. Press [Start/Pause] button 2 times. Does the drum rotate at low spin speed? Is it disconnected or badly contacted? [White : 2 pin ( ), Black : 2 pin ( ), White : 3 pin ( ), Blue : 4 pin ( ), White : 4 pin ( )] Check the motor connector, Is the resistance between the terminal in figure the same as below? Resistance between terminals .. ~ .. : 0.5 ~ 1.0. .. ~ . : 1.5 ~ 2.5. Be sure to unplug the machine before measuring. MOTOR TERMINAL Replace the PWB assembly. While spinning, is the frequency of the water level 248 or more. The frequency can be checked by p...
Ce manuel est également adapté pour les modèles :Rondelles - WD-10480N (1.7 mb)
Rondelles - WD-10480NV (1.7 mb)
Rondelles - WD-10480S (1.7 mb)
Rondelles - WD-10481N (1.7 mb)