Log:
Évaluations - 2, GPA: 4.5 ( )

Instructions LG, Modèle WD-10492S

Fabricant : LG
Taille : 1.7 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


When disconnecting the connector (1) on the PWB assembly (Main) is the resistance of the Natural connectors [..(Blue White), ..(White)] between 2.5k. to 180k.(105°C~0°C)? When checking thermistor on the tub, is the thermistor loosened above 2mm from the rubber? HEATING CONTINUOUSLY ABOVE THE SETTING WATER TEMPERATURE 23 NO YES YES YES NO NO NO YES 1 10 5 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 SPIN TROUBLE Check the sensor (Pressure) or hose (Sensor). If the problem is on the sensor or the hose, replace the sensor or the hose. Normal Reconnect or repair it. Replace the motor assembly. Press [Power] button with [Temp] and [Option] buttons pressed after power off. Press [Start/Pause] button 2 times. Does the drum rotate at low spin speed? Is it disconnected or badly contacted? [White : 2 pin ( ), Black : 2 pin ( ), White : 3 pin ( ), Blue : 4 pin ( ), White : 4 pin ( )] Check the motor connector, Is the resistance between the terminal in figure the same as below? Resistance between terminals .. ~ .. : 0.5 ~ 1.0. .. ~ . : 1.5 ~ 2.5. Be sure to unplug the machine before measuring. MOTOR TERMINAL Replace the PWB assembly. While spinning, is the frequency of the water level 248 or more. The frequency can be checked by pressing the [Spin] and [Temp.] buttons at the same time on the program. 9. DISASSEMBLY INSTRUCTIONS Be sure to unplug the machine out of the outlet before disassembling and repairing the parts. PLATE ASSEMBLY (TOP) CONTROL PANEL Unscrew 2 screws on the back of the top plate. Pull the top plate backward and upward as shown. Disconnect the PWB Assembly connector from Main lead wire Assembly. Pull out the drawer and unscrew 2 screws. Push upper hooks down on the top and pull the control panel. Disconnect the PWB assembly from the control panel by unscrewing 5 screws. 24 DRAWER DISPENSER ASSEMBLY DRAWER DISPENSER ASSEMBLY Disassemble the top plate assembly. Pull out the drawer to arrow direction. Unscrew 2 screws. Option DISPENSOR ASSEMBLY Disassemble hose and its clamps. Disassemble ventilation bellows and water inlet bellows on the tub. 25 1 2 3 INLET VALVE 1 2 3 INLET VALVE DOOR Disconnect the wiring receptacle. Unscrew 2 screws from the back. When reconnecting the connector VALVE #1 (MAIN) White/Black-Black VALVE #2 (PRE) Black - Gray VALVE #3 (HOT) Blue/White - Black LOWER COVER Open the lower cover cap by using coin and pull out the lower cover to the arrow direction after a screw is unscrewed. Open the door completely. Remove the two screws from the hinge. When removing the door assembly, it is necessary to hold the bracket that is inner of the cabinet cover. 26 GASKET ASSEMBLY GASKET ASSEMBLY Take apart the cabinet gasket clamp. Unscrew 2 screws from the cabinet cover. Open the lower cover cap and unscrew 1 screw inside. Take apart the lower cover. Disassemble the cantrol panel. (refer to the page 25) Unscrew all the screws on the upper and lower sides of the cabinet cover. Take apart the tub gasket clamp. Make sure that the drain hole of the...

Ce manuel est également adapté pour les modèles :
Rondelles - WD-10480N (1.7 mb)
Rondelles - WD-10480NV (1.7 mb)
Rondelles - WD-10480S (1.7 mb)
Rondelles - WD-10481N (1.7 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories