Log:
Évaluations - 4, GPA: 3.8 ( )

Instructions Zephyr, Modèle AHZ-M90ARX

Fabricant : Zephyr
Taille : 2.16 mb
Nom Fichier : ahz_manual_en.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


E. Watch constantly the fried food in order to avoid the cooking oil fl ares up. F. before performing any mainteinance operation, disconnect the hood from the electrical service. The manufacturers will not to accept any responsability for eventual damages, because of failure to observe the above instructions. - 6 - List of Materials Control Electrical Junction Box Glass Glass Light Bulbs Decorative Mesh Filters Range Hood Body Top Cover TYPE DESCRIPTION N° A M4 1 + 1 B 1/8" x 1/4" 12 C 1/8" x 2/4" 4 D 1/4" x 2-3/4" 6 - 7 - Ducting Calculation Sheet Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet. - 8 - Hood Specifi cations front of hood side of hood top of hood - 9 - Installation - Internal Blower NOTE! The device in this version (with internal suction blower) is equipped for rear discharge of exhaust air. However, if required, it is possible to have the exhaust air discharged from the top. This can be accomplished by carrying out the steps indicated in the following paragraphs; upon reaching step 4, the motor plate must not be rotated. The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fi re and electric shock, install this rangehood only with internal blower models MT-020 provided with the kit code CBI-600A. For external and in-line blower preparation please turn to page 13. 1. Unclip the top cover. Fig.1 2. Remove the 6” round metal knockout plate from the blower plate by using a fl at head screwdriver. See.Fig.2 3. Remove the (6) screws securing the blower plate to the blower housing and remove blower plate. See. Fig.3 - 10 - Installation - Internal Blower 4. Rotate the blower plate (Note! If air is discharged from the top, do not rotate the plate).Place the 6" metallic fl ange on the blower's air outlet (the fl ange may already be pre-installed). Install internal blower into blower plate and secure using (4) screws included with the blower. See Fig.4 5. Fasten the two brackets to the sides of the blower by fi xing them onto the blower plate with the (4 type B) screws, and to the sides of the blower with other (4 type C) screws. Fig 5 6. Secure capacitor box connected to the provided cable to the blower plate using (2 type B) screws included with the blower. See. Fig.6 7. Secure Green/Yellow ground wire connected to the cable to the provided capacitor to blower plate. (type A). Fig.7 - 11 - 8. Attach the 6 pin male molex connector from blower wire to the 6 pin female molex connector located inside the blower housing. See Fig.8 9. Install the blower and plate on the inside of the blower housing: carry out the instructions at step 3 in reverse order then use the screws provided to complete installation. (Tot. 12 type B). Fig.9 10. Open the fl ap Fig.10. Connect 9 pin male molex connector from blower wire to 9 pin female molex connector on the capacitor wire. See Fig.11 WARNING! Place electrical wiring inside the blower housing. 11. Close the fl ap until it clicks into place and put the top cover back on. The hood is now ready to be installed on the wall. Installation - Internal Blower - 12 - NOTE! The device in this version (with external blower) is equipped for rear discharge of exhaust air. However, if required, it is possible to have the exhaust air discharged from the top. This can be accomplished by carrying out the steps indicated in the following paragraphs; upon reaching step 5, the blower plate must be rotated and installed in the opposite direction. The following instructions are for preparing the hood for use with an external or in-line blowers models CBE-1000 or PBN-1000A. CAUTION: To reduce the risk of fi re and electric shock, install this rangehood only with remote blowers rated maximum 6.2 A. For internal blower instructions please turn to page 10. 1. Unclip the top cover. Fig.1 2. Remove the metal blower plate by striking it with the aid of a slotted screwdriver Fig.2 3. Remove the (6) screws securing the blower plate to the blower housing and remove blower plate. See.Fig.3 4. Install the flange and fix it to the blower plate with the (4 type B) screws. Fig 4 Installation - External & In-Line Blower Preparation - 13 - 5. Install the plate with the fl ange facing the wall, inside the motor casing: carry out the instructions at stage 3 in reverse order then use the screws provided to complete installation. (Tot. 12 type B). (Note! If air is discharged from the top, rotate the plate and install it in the opposite direction with the fl ange facing upwards) Fig.5 6. Put the top cover back on. 7. Open the fl ap Fig.6 8. With the aid of a slotted screwdriver, break the grommet of circular hole through which the wires pass. Fig. 7 9. Insert the female connector in the terminal box already attached to the hood. Fig. 8A Installation - External & In-Line Blower Preparation - 14 - Pass the wires of the remote...

Ce manuel est également adapté pour les modèles :
Ventilateurs - AHZ-M90AWX (2.16 mb)
Ventilateurs - AHZ-M90ABX (2.16 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories