Log:
Évaluations - 2, GPA: 3 ( )

Instructions Zephyr, Modèle AHZ-M90AWX

Fabricant : Zephyr
Taille : 2.16 mb
Nom Fichier : ahz_manual_en.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


See Fig. 9 Note2: Check local codes to determine minimum wire gauge. See manual included with external and in-line blower for instructions on installing the blower. Installation - External & In-Line Blower Preparation - 15 - Installation - Ducting Options WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certifi ed Silver Tape or Duct Tape. Some Ducting Options - 16 - MOUNTING HEIGHTS The range hood must be installed at a minimum height of 22 inches (56 cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood duct to the same duct used to exhaust hot air or fumes from another appliance. Before proceeding with the assembly instructions remove the decorative mesh filters so that the range hood is easier to handle. MOUNTING TO THE WALL 1. Place the paper template included with Installation your hood on the wall to determine where to add the screws for mounting the hood. Make sure that the line at the bottom of the template is aligned with the edge of the rear lower corner of the hood. Fig. 13 Note! Cut out holes for ducting if venting out the back. Drill holes for the power supply and the remote blower power supply (if required), using the measurements indicated in Fig.14 2. Fix the power supply conduit to the hole on the hood. If the hood has an external motor, fix the motor’s power supply conduit to the hole on the hood as well. Fig.15 - 17 - Installation - Mounting the Range Hood 3. Lift the hood onto the screws (type D) and adjust to make sure the hood is level. 4. When the hood has been adjusted tighten the screws to secure the hood in place. NOTE: Screws must be fastened into wooden studs so wood blocking may be necessary. If using wall anchors make sure to check your local codes for suitability and type of anchors to use. NOTE1: For the various installations use screws and screw anchors suited to the type of wall (minimum screw size: 1/4" diameter x 2-3/4" length). NOTE2: The following Duct Cover kits are available as acessories: Z1C-00HZ and Z1C-01HZ. - 18 - Installation - Power Supply Connection GENERAL • Carefully read the following important information regarding installation safety and maintenance. Keep this information booklet accessible for further consultations. POWER SUPPLY CONNECTION For connection to the power supply refer to the following: 1. Open the fl ap Fig.16 2. Remove the power supply cover by undoing the (2) screws Fig. 17. 3. Connect the wires of the hood to those of the power supply as described. Fig.18 : BLACK = L line WHITE = N neutral GREEN / YELLOW = G ground - A double-pole switch properly rated must be installed to provide the range hood power supply disconnection. - Connect the electrical conduit to the Field Wiring Compartment using listed conduit fi ttings. - Carry out the power supplly connection in accordance with the national electric code, ANSI/NFPA 70-1999. 4. Insert the wires into the box, then close the box cover, securing it using the screws that were previously removed. 5. Close the fl ap until it clicks into place. - 19 - Maintencance MAINTENANCE • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the regularity of maintenance. • The decorative mesh filters capture the grease particles suspended in the air and are therefore subject to clogging because of frequent use. In order to prevent a fire hazard, it is recommended to clean the filter a minimum of every 2 months or when instructed by the Metal Filter Clean indicator on the range hood controls. Clean the range hood by carrying out the following instructions: - Remove the filters from the range hood and wash them in a solution of water and neutral liquid detergent, leaving to soak. - Rinse thoroughly with warm water and leave to dry. - Filters may also be washed in the dishwasher at the lowest setting. The filters may alter in color after several washes but is not cause for replacement. • Clean the blower and other surfaces of the range hood regularly using a cloth moistened with denatured alcohol or non abrasive liquid detergent. - 20 - DESCRIPTION HOOD PART# REPLACEMENT PARTS Light Bulb GU5, 20W (each) AHZ Z0B0031 OPTIONAL ACCESSORIES Recirculating Kit AHZ ZRC-00HZ Replacement Charcoal Filters AHZ Z0F-00AC Short Duct Cover (8”-9” ceiling) AHZ Z1C-00HZ Long Duct Cover (9”-10” ceiling) AHZ Z1C-01HZ Black Glass with Flower Pattern AHZ AHG-00BL White...

Ce manuel est également adapté pour les modèles :
Ventilateurs - AHZ-M90ARX (2.16 mb)
Ventilateurs - AHZ-M90ABX (2.16 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories