Log:
Évaluations - 3, GPA: 3.3 ( )

Instructions Best, Modèle COOKER HOOD DF 6260

Fabricant : Best
Taille : 613.74 kb
Nom Fichier :
Langue d'enseignement: enfrdenl
Aller à la télécharger



Facilité d'utilisation


The switch must be accessible at all times. The following is valid in the United Kingdom only: -the wire which is coloured green and yellow must be connected to the terminal which is marked with the letter E or by the earth symbol ( ), or coloured green or green and yellow; -the wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black, - the wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. Installation Preparing the wall unit - Extractor version • The hood is supplied as an extractor unit. Before installing the hood, drill a hole in the roof of the wall unit (see item. 5). This hole is to allow passage of the outlet pipe and the power cable, and to facilitate servicing. • The wall unit must have a minimum body depth (without door) of 300 mm with recessed Fig. 5 light screen and min. 370 mm with flush-mounted light screen. The unobstructed internal height must be at least 370 mm. Preparing the wall unit - Filter version (DF 6160) • Before installation of the hood in the wall unit, a 115x115 mm hole for the deflector should be cut in the ceiling of the wall unit. Fig. 6-7. • Depending on the wall unit height, you need for return air operation a pipe union or additionally a non-flammable length of pipe (O 100/115/ 120 mm) as far as the ceiling of the wall unit. Fig. 6 Fig. 7 72 Outlet hole - Only for models DF 6260, DF 6260-ml/1 and CHDF 6260 (extractor-filter version) • When used as an extractor unit, the hood must be fitted with a 150mm diameter hose. Only for model DF 6260 - DF 6260-ml/1: Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof, it is possible to use the 150/125 mm reduction flange provided. In this case the hood will be slightly more noisy. Fix the flange on the hood outlet hole, using 2 screws. Fig. 8a. Filter version only • Fix the deflector to the flange. Fig. 8b. Outlet hole - Only for model DF 6160(extractor-filter version) • When used as an extractor unit, the hood must be fitted with a 120mm diameter hose. • The dimensions and position of the air outlet are given in figure 9. • Using the adapter, O100, O110 and O125 mm exhausting pipes can be used. O 125 mm exhausting hose: insert the adapter on the flange and remove, using a proper tool, the upper unused O 100 and O 110 mm rings of the adapter. O 110 mm exhausting pipe: same procedure, but removing the O 100 mm ring only. O 100 mm exhausting pipe: apply the adapter on the flange. Fig. 8a Fig. 8b Fig. 9 Fig. 10 A Spice rack • If a spice rack is to be incorporated in front of the hood, a minimum distance of 5 mm must be provided between the front edge of the fume extractor hood and the spice rack wall (this air gap being necessary for air circulation). • The upper part of the spice rack rear wall should be detachable (access for exhaust air hose or adjustment of furniture housing). Installing the extractor h...

Ce manuel est également adapté pour les modèles :
Ventilateurs - COOKER HOOD CHDF 6260 (613.74 kb)
Ventilateurs - COOKER HOOD DF 6160 (613.74 kb)
Ventilateurs - COOKER HOOD DF 6160 (613.74 kb)
Ventilateurs - COOKER HOOD DF 6160 (613.74 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories