Log:
Téléchargements : 0   Taille : 58 kb   Fabricant : Emerson  
Catégorie : Ventilateurs
@name

You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: All components are covered by this warranty for one year from the date you purchased your light fixture. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR. What Will Emerson Electric Co. Do To Correct Problems: Emerson Electric Co. will replace a defective Emerson Light Fixture at no charge

Téléchargements : 1   Taille : 203 kb   Fabricant : Emerson  
Catégorie : Ventilateurs
@name

Figure 4 NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wiring. 2. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 4). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 4). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on

Téléchargements : 1   Taille : 203 kb   Fabricant : Emerson  
Catégorie : Ventilateurs
@name

Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when: • The original purchaser or user ceases to own the product, or • The fan is moved from its original point of installation. This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Comp

Téléchargements : 5   Taille : 203 kb   Fabricant : Emerson  
Catégorie : Ventilateurs
@name

Engage the connector of the switch cup assembly with the motor connector by aligning the V-notch shaped keyways and pressing the connectors firmly together until they fully mate. The V-notch keyways prevent the connectors from being engaged improperly. 14. Position the switch cup assembly on the motor switch plate and align the holes in the cup assembly with the holes around the side of the switch cup plate. Secure The switch cup assembly by installing three 8-32 x 3/8" flat head screws (supplie

Téléchargements : 3   Taille : 203 kb   Fabricant : Emerson  
Catégorie : Ventilateurs
@name

8 Attaching Light Kit WARNING ! To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. To install an accessory light kit, remove the three screws securing the switch cup assembly to the fan, remove the switch cup assembly, and disconnect the connector. Remove the screw plug from the bottom of the switch cup and install the light kit in accordance with the light kit Owner's Manual. Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Peri

Téléchargements : 5   Taille : 203 kb   Fabricant : Emerson  
Catégorie : Ventilateurs
@name

half of styrofoam unit. Remove parts and check to see that you have received the following: a. Fan motor and housing assembly b. One motor cover c. One ceiling cover d. Five blade flanges e. One hanger ball/downrod assembly f. One hanger bracket g. One housing switch cup h. One loose parts bag containing: 1. One setscrew 2. One 3/16" hex wrench 3. Eleven 10-32 x 5/8" oval head screws 4. Two 1” threaded studs 5. Two 1-1/4” threaded studs 6. Four knurled knobs 7. Three wire connectors 8. Four 8-32

Téléchargements : 0   Taille : 203 kb   Fabricant : Emerson  
Catégorie : Ventilateurs
@name

. #8 Washerhead, (4) — — — — — — — — — — — 29 Washer, 9/16” — — — — — — — — — — — — Owner's Manual BP7234-3 BP7234-3 BP7234-3 BP7234-3 BP7234-3 BP7234-3 BP7234-3 BP7234-3 BP7234-3 BP7234-3 BP7234-3 *Contact your nearest ! WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 2. Loose power line connections to the fan, or loose sw

Téléchargements : 7   Taille : 205 kb   Fabricant : Emerson  
Catégorie : Ventilateurs
@name

NOTE: Place the parts from the loose parts bags in small containers to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding. NOTE: Fan blades are ordered separately and are packaged in separate carton. LOOSE PARTS BAG BLADE FLANGES SWITCH HOUSING COVER HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBLY CEILING COVER FAN MOTOR AND HOUSING ASSEMBLY MOTOR COVER 1. Open styrofoam unit containing fan. Remove top half of styrofo

Téléchargements : 1   Taille : 205 kb   Fabricant : Emerson  
Catégorie : Ventilateurs
@name

Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician. 3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as acceptable for fan support, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support o

Téléchargements : 1   Taille : 205 kb   Fabricant : Emerson  
Catégorie : Ventilateurs
@name

Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble. WARNING ! It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling. 9. The fan comes with blue, black and white leads that are 80” long. Before installing fan, measure up approximately 6 to 9-inches above the b





catégories