Note: Electronic models must be connected to the main power supply. 1. Route a 3-wire 120Vac 60Hz 1ph power supply to the appliance junction box. 2. Remove the electrical inlet cover plate from the side of the unit by removing the plate’s securing screws (see Figure 10 on Page 9). 3. Remove the cover plate knockout; then feed the power supply wire through the knockout opening and into the unit junction box. 4. See Figure 17. Connect the black power supply wire to the lower outlet’s red pigtail lead. Connect the white power supply wire to the outlet’s common terminal. 5. Connect the ground supply wire to the pigtail lead attached to the outlet’s green ground screw. Note: Remote receiver should be located in the wall, or if installed in the control compartment, pulled all the way forward and completely to the Figure 16: Wiring Diagram—Electronic Gas Valves left or right against the corner posts. P/N 580491-01 JUNCTION BOX 120V AC REMOTE RECEIVER ON/OFF SWITCH WALL SWITCH SAFETY LIMIT SWITCH B-VENT MODELS ONLY AC/DC POWER ADAPTOR HOT NEUTRAL OPTIONAL GROUND BATTERY HOLDER DFC WIRE HARNESS SPARK WIRE CABLE PILOT GROUND WIRE PILOT SENSOR CABLE HOOD IGNITER ROD FLAME SENSOR PILOT TUBE CPI SWITC H OFF (O) = INTERMITTENT PILOT MODE ON (-) = STANDING PILOT MODE PROFLAME DFC BOARD PROFLAME VALVE ELECTRONIC PILOT ASSEMBLY B = BLACK BR = BROWN GY = GRAY PU = PURPLE R = RED BL = BLUE G = GREEN O = ORANGE W = WHITE Y = YELLOW WIRING COLOR CODE B B B R R W W B B B B BL BL G G O Y Y R R Y W G G O SCHEMATIC REPRESENTATION ONLY Figure 14: SIT Milivolt Wiring Diagram If any of the original wire as supplied must be replaced, it must be replaced with Type AWM105 ° C – 18 GA. wire. Thermopile T H TP T H TP *TWIST WIRES “ A ” AND “ B ” TOGETHER TO OPERATE UNIT SOLELY BY MANIPULATING THE GAS VALVE CONTROL KNOB; OR CONNECT WIRES TO OPTIONAL ON/OFF SWITCH OR WALL SWITCH OR REMOTE CONTROL RECEIVER TO OPERATE UNIT *OPTIONAL ON/OFF SWITCH, WALL SWITCH, OR REMOTE CONTROL RECEIVER A B L IM I T S W IT C H BK WT BK BK Schematic Representation Only Figure 15: Optional J-Box/Outlet Box (Left Side Shown) See Figure 10 on Page 10 for Optional Electrical Inlet Knockout Location. * Field-Provided Junction Box and Duplex Receptacle * Narrow (2-1/8 Inch Wide) J-Box Required CAUTION: ENSURE THAT WIRES ARE POSITIONED AWAY FROM HOT SURFACES AND SHARP EDGES. LENNOX HEARTH PRODUCTS • MERIT PLUS® B-VENT GAS FIREPLACES (MPB33/35/40/45) • INSTALLATION INSTRUCTIONS 6. If wall-mounted ON/OFF control is to be used, mount it in a convenient location on a wall near the fireplace. 7. If an optional control is to be used, wire it in the low voltage circuit as shown in Figure 16. Note: The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment. 8. After the wiring is complete, replace the cover plate. WARNING Electronic models of these appliances are equipped with a three- prong...
Ce manuel est également adapté pour les modèles :Cheminées - MERIT PLUS MPB3328CNE-B (2.39 mb)
Cheminées - MERIT PLUS MPB4540CNM-B (2.39 mb)
Cheminées - MERIT PLUS MPB4540CNE-B (2.39 mb)
Cheminées - MERIT PLUS MPB4035CNM-B (2.39 mb)