Log:
Téléchargements : 9   Taille : 354 kb   Fabricant : HP  
Catégorie : matériel de pompage
@name

The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance. 1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication. 2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joi

Téléchargements : 10   Taille : 354 kb   Fabricant : HP  
Catégorie : matériel de pompage
@name

It maybe necessary to use a slide hammer tool. 4) Inspect valve seats (46A) and valve plates (46B) for damage and replace if needed. Check valve casing (43) surfaces for damage. Replace o-rings (44A) and reinstall valve assemblies (46) into valve casing. (Lubricate o-rings before installation.) SEAL AND PLUNGER REPLACEMENT 6) Remove the eight (8) manifold nuts and washers (49A,B) using a 19mm wrench and pull off valve casing (43). 7) If needed, tap valve casing with a rubber mallet to remove

Téléchargements : 8   Taille : 354 kb   Fabricant : HP  
Catégorie : matériel de pompage
@name

105 lbs. Crankshaft Diameter...............................................................................35mm PULLEY INFORMATION Pulley selection and pump speed are based on a 1725 RPM motor and "B" section belts. When selecting desired GPM, allow for a ±5% tolerance on pumps output due to variations in pulleys, belts and motors among manufacturers. 1. Select GPM required, then select appropriate motor and pump pulley from the same line. 2. The desired pressure is achieved by selecting th

Téléchargements : 6   Taille : 263 kb   Fabricant : HP  
Catégorie : matériel de pompage
@name

This warranty does not cover freight damage, freezing damage, pump or motor damage from incorrect wiring (if equipped with motor), normal wear and tear, or damage caused by misapplication, fault, negligence, alterations, dry running pump, or repair that affects the performance or reliability of the product. THIS WARRANTY IS EXCLUSIVE. HYPRO MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Hypro’s obliga

Téléchargements : 8   Taille : 263 kb   Fabricant : HP  
Catégorie : matériel de pompage
@name

Protect yourself and others by observing all safety information. The Safety Instructions are contained in the General Operating Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions for future reference. Carbonator-Mount Rotary Close-Coupled External Gear Pumps Refer to form L-4082 for General Operating and Safety Instructions. Description Shertech self-priming, positive displacement, ext

Téléchargements : 5   Taille : 263 kb   Fabricant : HP  
Catégorie : matériel de pompage
@name

Note that seals and o-rings used in each material type are interchangeable. The Viton components from the cast iron models can be used in the bronze, and the Buna in the bronze models can be used in the cast iron models. Shertech Operating Instructions, Performance, Specifications and Parts Manual Bronze Models GCBN2V, GCBN3V, GCBN22V and GCBN33V Cast Iron Models GCCV2V, GCCV3V, GCCV22V and GCCV33V Repair Parts List Ref. Part No. For Model: No. Description GCBN2V GCBN3V GCCV2V GCCV3V GCBN22V GCB

Téléchargements : 7   Taille : 263 kb   Fabricant : HP  
Catégorie : matériel de pompage
@name

No 10) and replace with a new seal assembly. Refer to INSPECTION procedures below. 5. Remove the seal assembly spring and metal seat. 6. Remove external retaining ring (Ref. No. 9) from the shaft (Ref. No. 5) using external snap-ring pliers (21.2” legs). 7. Remove the gear assembly and drive shaft (Ref. No. 4 & 5). Pump Inspection Inspect components for signs of excessive wear. Excessive wear of the pump will usually show up as degradation of performance. This can be seen by the flow dropping of

Téléchargements : 7   Taille : 263 kb   Fabricant : HP  
Catégorie : matériel de pompage
@name

Figure 4 - Pressure Relief Valve Adjustment Protective cap Adjust pressure relief valve screw Loosen lock nut 9. To convert the relief valve to external relief, remove the 1/4 NPT pipe plug from the pump cover (Figure 5 & 7, Ref. No. 13) and discard. This plug is next to the relief valve. In the bottom of the 1/4 NPT hole, there is a second drilled and tapped Figure 5 - External Bypass Installation Optional external bypass plug Remove and discard plug Form L-4083 (1/06) 7 Shertech Operating Inst

Téléchargements : 7   Taille : 263 kb   Fabricant : HP  
Catégorie : matériel de pompage
@name

Form L-4083 (1/06) 6 Shertech Operating Instructions, Performance, Specifications and Parts Manual Bronze Models GCBN2V, GCBN3V, GCBN22V and GCBN33V Cast Iron Models GCCV2V, GCCV3V, GCCV22V and GCCV33V 6. Be certain all suction piping connections are airtight. NOTE: Assure airtight pipe connections with the use of a pipe joint sealant. DISCHARGE 1. Attach discharge piping to the discharge outlet. Support pump and piping during assembly and after installation. Failure to do so may cause piping to

Téléchargements : 9   Taille : 263 kb   Fabricant : HP  
Catégorie : matériel de pompage
@name

For your protection, always wear proper clothing, eye protection, etc. in case of any malfunction. For proper handling techniques and cautions, contact your chemical supplier, insurance company and local agencies (fire dept., etc.). Failure to comply with this warning could result in personal injury and/or property damage. Form L-4083 (1/06) Shertech Operating Instructions, Performance, Bronze Models GCBN2V, GCBN3V, GCBN22V and GCBN33V Specifications and Parts Manual Cast Iron Models GCCV2V, GCC





catégories