Use SCREW DRIVER to attach POLE to BASE by inserting and turning the 2 screws tightly Screws 6. Slide POLE COVER down 5 Setting The Zero Point and Balance Before using the scale for the first time or when another place, you must set the zero point and weighing yourself. Zero Point 1. With nothing on the PLATFORM, adjust POINTER to ZERO using ADJUSTING KNOB found under DIAL, on the unit’s back side. Balance Adjusting Knob 1. Place the scale on a flat, firm surface 2. Turn 6 LEVELING FEET until th
40E 2, 1" Long 3788200 Snubber, Filter Pressure Gauge 41A 1 1289101 115V Relay (for Remote Blower on XPert Filtered Station) 41B 1 1289102 230V Relay (for Remote Blower on XPert Filtered Station) 42 1 3925600 Harness, Relay (for Remote Blower on XPert Filtered Station) 76 Appendix A: Replacement Parts s Use for XPert System and XPert Station 23 17 22 26 7 21 32 35 31 33 Placed on ledge above HEPA filter 34 24 25 28 29 30 36 9 11 1 10 63 4 5 12 14 13 40 19 18 8 16 20 2 77 Appendix A: Replacement
The display will turn on, and automatically turn off. The scale is now ready for use. Note: The scale may need to be initialized if it is moved or bumped. General Operation 1. Place the scale on a flat, hard surface. Carpeted or uneven floors may affect accuracy. 2. Step on the scale, positioning your feet evenly on the scale platform. Stand still while the scale measures your weight. 3. When your weight stabilizes, the display will show your weight. remain on the screen for a few seconds. The d
HEPA Carbon Carbon Carbon Important: Carbon filters do not provide any particulate protection, but provide odor control. Connecting the Electrical SupplySource to the Filtered Enclosure 115V Models Simply connect the 115V power cord supplied to the IEC electrical supply plug on the back of the enclosure. If using at 50 Hz operations, blower performance maximum airflow will be reduced by 17%. For the remote blower used for XPert Stations, follow the wiring diagram in Appendix C and wire the blowe
Width Catalog # Size 2' 3776003 48" Circum. x 54" lg. 3' 3776004 73" Circum. x 96" lg. 4' 3776005 96" Circum. X 96" lg. Odor Control Carbon Filter Provides granular activated carbon or impregnated carbon used for Odor Control applications on integral motorized impeller models exhausted back into the room. Filter Classification and Size Catalog # X Pounds 2' Organic 18 x 18 x 1 3937200 5.5 lbs. activated 3' Organic 30 x 18 x 1 3937300 9.2 lbs. activated 4' Organic 42 x 18 x 1 3937400 12.9 lbs. ac
S.S. 19 1 3926800 Label, Front XPert 20A 1 3910700 Airflow Switch 20B 2 1891808 Screw, Thread Cutting #6-32 x .50 PH 21 Multiple 1905617 Nut, KEPS 10-24 22 2 1307000 Switch, Rocker (2 position) 23A 1 or 2 3904800 Front Panel, 2' 23B 1 3904801 Front Panel, 3' 23C 1 3904802 Front Panel, 4' 23D 1 3904803 Front Panel 2' with Digital Monitor Cutout 23E 1 3904804 Front Panel, 3' with Digital Monitor Cutout 23F 1 3904805 Front Panel, 4' with Digital Monitor Cutout 23G 2 4472400 Screw, Thread cut 10-24
See Figure 4-1 15. Fluorescent Lamp is located above the work area, out of contact with contaminated air. A safety glass window beneath the lamp distributes the light evenly across the work surface. See Figure 4-1. 16. Filter System Pressure Gauge indicates the total system pressure across the HEPA filter and pressurized plenum to help predict HEPA filter loading. See Figure 4-1. 17. Filter Clamping Bolt evenly seals the HEPA filter to the frame of the enclosure. See Figure 4-1 and 4-2. 18. Sash
The filtered enclosures have been tested to effectively contain toxic and noxious materials when properly installed and operated. What makes the filtered enclosures so unique is the revolutionary way they direct air into and through the contaminated air chamber. Labconco engineered the filtered enclosures to minimize the effects of turbulence. The containment-enhancing and aerodynamic designs of the upper sash foil, side air foils, lower air foil, upper dilution air supply, and rear perforated b
See Figure 4-1 15. Fluorescent Lamp is located above the work area, out of contact with contaminated air. A safety glass window beneath the lamp distributes the light evenly across the work surface. See Figure 4-1. 16. Filter System Pressure Gauge indicates the total system pressure across the HEPA filter and pressurized plenum to help predict HEPA filter loading. See Figure 4-1. 17. Filter Clamping Bolt evenly seals the HEPA filter to the frame of the enclosure. See Figure 4-1 and 4-2. 18. Sash
The PCB has also a two-pin connector for use as an external output with isolated relay contacts that close when the red/alert LED is lit (low airflow). These relay contacts are not affected by the “SILENCE ALARM” button. The PCB is mounted behind the front panel using standoffs and an appropriate label is used to highlight the “SILENCE ALARM” button with clear areas for the red and green LED’s. No holes to allow sound to be broadcast louder are necessary. The PCB can be prepared as a factory spe