Log:

FMI FMH26TP

Téléchargements : 14 Taille : 753 kb    Fabricant : FMI  
Catégorie : Cheminées

Use a No. 16 AWG cord for lengths less than 50 feet. Attaching Wood Base to Solid Floor For attaching base to solid floors (concrete or masonry) Note:Floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace. 1. Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep. 2. Fold floor anchor as shown in Figure 22. 3. Insert floor anchor (wings first) into hole. Tap anchor flush to floor. 4

FMI FMH26TN

Téléchargements : 1 Taille : 732 kb    Fabricant : FMI  
Catégorie : Cheminées

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be per- formed by a qualified installe

FMI FVFM27PR

Téléchargements : 2 Taille : 725 kb    Fabricant : FMI  
Catégorie : électrique

Open damper or window to vent smell. This will only last a few hours. Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the High heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat. WARNING: Damper handle will be hot if heater has been running. 1. STOP! R

FMI Gussofen G3

Téléchargements : 0 Taille : 526 kb    Fabricant : FMI  
Catégorie : Cheminées

Your professional dealer or distributor knows these laws. Please have your certified retailer carry out the connection of your stove. 3. CORRECT OPERATION OF YOUR STOVE Initial startup of your stove Your stove was treated with a special environmentally friendly lacquer. The lacquer surface is still soft when the stove is delivered. The lacquer will harden when your stove is used for the first time. The lacquer surface must not be touched when it is heated for the first time. The stove must be in

FMI Becton 7 mk3

Téléchargements : 5 Taille : 525 kb    Fabricant : FMI  
Catégorie : Cheminées

Ensure the rear matrix is pushed back against the location bar. (Fig 4b) Fig 4b Step 3 Becton 7 only. Locate 2 off end coals each side of the base matrix. (See underside of coals for hand identification) (Fig 4c). Fig 4c Becton Bunny & Becton 7 mk3 Gas stoves OPERATING INSTRUCTIONS LIGHTING & CONTROLLING THE FIRE Under no circumstance must the fire be operated if the glass is cracked or broken. Open the gas control access door situated at the bottom of the appliance. Always use the control door

FMI Becton Bunny

Téléchargements : 17 Taille : 525 kb    Fabricant : FMI  
Catégorie : Cheminées

See "SAFETY NOTICES" ref coal set page 4. Ensure the appliance is cold. Step 1 Isolate the gas supply to the fire using the gas cock supplied at installation. Step 2 Open the fire door, (Held closed using a magnet). Step 3 Remove the glass frame and the glass/ gasket assembly. Step 4 Carefully remove and clean the coal set of any soot deposits using a soft brush. Step 5 Carefully remove and clean the firebox linings. Where necessary. Step 6 Inspect the chimney and flue terminal ensuring they are

FMI VFN30R

Téléchargements : 1 Taille : 498 kb    Fabricant : FMI  
Catégorie : électrique

After 30 seconds, release control knob. Now follow steps 9 through 11, Lighting Instructions, column 1. OPTIONAL REMOTE OPERATION Note:All remote control accessories must be purchased separately (see Accessories, page 24). Follow instructions included with the remote control. Thermostat Control Operation (Optional GHRCTA Series Only) The thermostat control setting on the remote control unit can be set to any comfort level between WARMER and COOLER. The burners will turn on and off automatically

FMI VFN24R

Téléchargements : 3 Taille : 498 kb    Fabricant : FMI  
Catégorie : électrique

Follow all local codes. Installation Items Needed Before installing heater, make sure you have the items listed below. • piping (check local codes) • sealant (resistant to propane/LP gas) • equipment shutoff valve * • test gauge connection * • sediment trap • tee joint • pipe wrench * An CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly kn

FMI VFN18R

Téléchargements : 1 Taille : 498 kb    Fabricant : FMI  
Catégorie : électrique

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling A. Clearances from the side of the fireplace cabinet to any combustible material and wall should follow the diagram in Figure 4. Example:The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 4). Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer

FMI VFP24MV

Téléchargements : 0 Taille : 465 kb    Fabricant : FMI  
Catégorie : Radiateurs à gaz

UNVENTED PROPANE/LP GAS LOG HEATER CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burners, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair,etc. CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air





catégories