Log:

American Sensor COS2010

Téléchargements : 1 Taille : 780 kb    Fabricant : American Sensor  
Catégorie : Alarme incendie

carbon monoxide in the air, exposure time and health effects. ceiling. A. INTRODUCING THE AMERICAN SENSORS COS2010 • Keep your family in a pre-arranged meeting place after your escape. For most people, mild symptoms generally will be felt after several hours Dirt and Blockage • In high humidity areas such as bathrooms and attics, place at least 10 If you have any questions regarding this unit , call CARBON MONOXIDE & SMOKE ALARM feet (3 m) away from bathrooms. of exposure to 100 ppm of carbon mo

American Sensor CO910

Téléchargements : 2 Taille : 466 kb    Fabricant : American Sensor  
Catégorie : Alarme incendie

Exposure Times The carbon monoxide concentrations and time standards for the alarms are as follows: The Full Alarm Activates • Within 60–240 minutes at exposures of 70 ppm • Within 10–50 minutes at exposures of 150 ppm • Within 4–15 minutes at exposures of 400 ppm WARNING: O. Warranty Information 5 Year Limited Warranty Dicon Global Inc., which manufactures American Sensors Carbon Monoxide Alarms, warrants its product, to the original consumer purchaser, to be free from defects in material and w

American Sensor CO920

Téléchargements : 4 Taille : 466 kb    Fabricant : American Sensor  
Catégorie : Alarme incendie

This will silence the alarm for up to 6 minutes. If the unit re-alarms after reset it confirms the ongoing presence of harmful levels of carbon monoxide. I. How can you replace your back-up battery? How to replace the battery 1. Unplug alarm from outlet; battery is at the bottom on back of unit 2. Push battery to left to remove from plastic spring 3. Remove existing 9 volt battery 4. Insert fresh 9 volt battery into terminals. Push battery and wires back into enclosure. Use only recommended batt

American Sensor CO900

Téléchargements : 2 Taille : 466 kb    Fabricant : American Sensor  
Catégorie : Alarme incendie

Young children and household pets may be the first affected. Exposure during sleep is particularly dangerous because the victim usually does not awaken. The amount of carbon monoxide in the air is measured as ppm (parts per million). The graph below shows the important relationship between carbon monoxide in the air, exposure time and health effects. For most people, mild symptoms generally will be felt after several hours of exposure to 100 ppm of carbon monoxide. Higher levels will lead to mor

American Sensor SA379

Téléchargements : 9 Taille : 391 kb    Fabricant : American Sensor  
Catégorie : Alarme incendie

This smoke alarm is also interconnectable with up to 11 other units. Important information about your smoke alarm € Install alarms outside of every bedroom area and on every floor of your home. Please refer to Section 3 •Where to Locate Smoke AlarmsZfor details. € Install the alarm as close as possible to the center of the ceiling. € Your Smoke Alarm is packaged with the back-up battery reversed. Connect it before mounting the unit. Ensure proper polarity of the battery. Alarm will •beepZif batt

American Sensor CB100

Téléchargements : 50 Taille : 352 kb    Fabricant : American Sensor  
Catégorie : Alarme incendie

CB100 INSTRUCTION MANUAL Page 1 This manual contains instructions for installing your American Sensors™ relay module. The relay module is ULC listed as an accessory for use only with American Sensors™ interconnectable smoke alarms in the 470L, 670L and 770L series, plus models SA360, SA379, ESA5011 and combination CO/Smoke alarm model C0S2010. WARNING: This relay will not operate without continuous AC power. Do not use with battery backup units. CAUTION: Do not interconnect Model No. CB100 t

American Sensor LP405

Téléchargements : 2 Taille : 315 kb    Fabricant : American Sensor  
Catégorie : Alarme incendie

Warranty Information Limited Warranty Dicon Global Inc. warrants its enclosed Propane Gas Detector sensor to be free from defects in material and workmanship under normal use and service for a period of five (5) years form date of purchase. Dicon Global Inc. warrants it's enclosed Propane Gas Detector other than the sensor to be free from defects in materials and workmanship under normal use and service for a period of one (1) year from date of purchase. Dicon Global Inc. makes no other express

American Sensor LP401

Téléchargements : 1 Taille : 315 kb    Fabricant : American Sensor  
Catégorie : Alarme incendie

The alarm sounds. To reset the alarm, turn the 12 Volt supply off, wait ten seconds, then turn it on again. A. Why should you be concerned about propane gas? Propane gas is a colorless, flammable gas that can be explosive if it escapes and builds up. Propane is stored as a liquid under pressure, so most likely sources of leaks are in the connections to propane tanks for propane-pow-ered heaters, stoves, refrigerators, furnaces, and barbecues. When propane leaks, it becomes a gas and can be i

American Sensor LP405A

Téléchargements : 22 Taille : 315 kb    Fabricant : American Sensor  
Catégorie : Alarme incendie

THIS DEVICE IS NOT SUITABLE FOR INSTALLATION IN A HAZARDOUS LOCATION, AS DEFINED IN THE NATIONAL OR CANADIAN ELECTRICAL CODE. Introducing the LP401, LP401A, LP405, LP405A Propane Gas Detector The LP401, LP401 A, LP405, LP405A Propane Gas Detectors are effective products for detecting any build-up of propane gas in your home. Dicon Global Inc., the maker of these propane gas detectors, has been developing and making products for detecting gases since 1985. Your new detector: • Is easy to inst

American Sensor LP401A

Téléchargements : 4 Taille : 315 kb    Fabricant : American Sensor  
Catégorie : Alarme incendie

It is normal for this light to turn on once or twice after you power the detector or after a power failure. A G What should you do if the ALARM sounds? EVACUATE IMMEDIATELY! Do a head count to check that everybody is accounted for. Call the nearest fire department and ask them to determine the source of propane gas. Do not re-enter the premises until the problem has been corrected and the propane gas has been dispersed. ! WARNING: Activation of this device indicates the presence of propane g





catégories