NOTE: DC convenience open systems are optional and your gate system may or may not be equipped with one. Check with your installer to determine if your gate system is equipped with a convenience open system. 3. In the event of a primary (AC) power failure and a back-up system (DC) power failure (low charged or dead batteries for example), the system must have a release system to allow the gate to be manually operated. 6500-065-K-7-08 27 • Be sure that power is removed or shut-off prior to placin
All rights reserved. WARNING MOVING GATE CAN CAUSE Operate gate only when gate area is in sight and free of people and obstructions. Do not allow children to play in gate area or operate gate. Do not stand in gate path or walk through path while gate is moving. Read owner’s manual and safety instructions. SERIOUS INJURY OR DEATH CLASS CERTIFIED TO CAN/CSA C22.2 NO. 247 CONFORMS TO ANSI/UL-325 VEHICULAR GATE OPERATOR HP 53382 MODEL SERIAL VOLTS PHASE AMPS 60 Hz MAX GATE LOAD DoorKing, Inc., Ingle
Auto-close timer (when turned on) SW 1, switch 4. Adjust from 1 second (full counter clockwise) to approximately 23 seconds (full clockwise). Dry relay contacts (terminals 16-17) can be set for Normally Open (NO) or Normally Closed (NC) operation by placing the relay shorting bar on the N.O. or N.C. pins respectively. 1 ON 2 3 4 5 6 7 8 SW 1 Loop Detector Loop Detector 1 23 9410 EXIT REVERSE SHADOW SHADOW OUTPUT 9409 Dry Relay Auto-Close Timer Contact 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4
All rights reserved. DoorKing, Inc. 120 Glasgow AvenueInglewood, California 90301 U.S.A. Phone: 310-645-0023Fax: 310-641-1586 Use this manual with the following models only. Model 1820 Telephone Intercom Systems with circuit board 1885-010, Rev A or higher. DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no r
The gate must reverse direction after striking the object. If it does not, increase the reverse sensitivity by turning the potentiometer 1/8 turn clockwise, then repeat this test. NOTE: After the gate has reversed, the operator will assume a "soft shutdown" making it necessary to initiate the cycle again by momentarily shorting across terminals 1 and 5 as in step 1. 7. Place an immobile object along the path of the gate so that the gate will strike it while in the close cycle. The gate must reve
Be sure that the operator mounting plate is parallel to the gate. 1.5 Mounting Stand Installation 1. Construct a form for the mounting pad according to the specifications shown below. Be sure to level the top edge of the form and that the top of the form is a minimum of four (4) inches above ground level. We suggest that you contact the local building department to determine the required depth of the pad since soil conditions and code requirements vary from city to city. 2. Set conduits, reinfor
This will help insure that your installation is performed in an efficient and professional manner. The proper installation of the vehicular slide gate operator is an extremely important and integral part of the overall access control system. Check all local building ordinances and building codes prior to installing this operator. Be sure your installation is in compliance with local codes. 1.1 Specifications Class of Operation: Class III, IV Type of Gate: Vehicular Slide Gates Only Horsepower: 9
All rights reserved. DoorKing, Inc. 120 Glasgow AvenueInglewood, California 90301 U.S.A. Phone: 310-645-0023Fax: 310-641-1586 Use this manual with the following models only. All 9310 models with circuit board 4403-010. IMPORTANT! The 4403 circuit board used in the model 9310 IS NOT interchangeable with the 4402 circuit board used in the earlier model 9300 operators. NOTE: Models 9310-081, 9310-083, 9310-085, 9310-087, 9310-089, 9310-091, 9310-093, 9310- 095 and 9310-097 will have a supplemental
Note that the electric strike and the magnetic lock are powered from their own power supply. The relay 2 contact is set to either normally open (NO) for electric strikes, or normally closed (NC) for magnetic locks by placing the relay 2 contact shorting bar on either the NO or NC pins. A variation of this diagram is for the system to control three doors, or two gate operators (entry and exit) and a door, or three gate operators. Text Box: 2.3.4 Tracker Expansion Board Control When Tracker expans
1. Press *24 and enter the four-digit MASTER CODE _ _ _ _ (beep). 2. Enter the area code reference number (0 through 9) _ then press * (beep). 3. Enter # # # # then press * (beep). 4. Repeat steps 2 and 3 to delete additional area codes. 5. Press 0# TOGETHER to end this programming step (beeeeeep). 3.5.9 Display Phone Numbers (1815, 1817 Systems Only) Use this programming sequence to display phone numbers programmed under known directory codes, i.e. if you wanted to see what phone number was pro