Flexible Metal Duct Exhaust Hood Type Exhaust Hood Type Qo Number Cat. No. Cat. No. B1V of WX8X59 WX8X59 H 90° (Preferred) B (Preferred) B Domestic 2-1/2 Turns A 2-1/2" A 2-1/2" Dryer Models 4" Opening Opening 4" Opening Opening 0 90 ft. 60 ft. 55 ft. 45 ft. 1 60 ft. 45 ft. 40 ft. 30 ft. Super & Extra-Large 2 45 ft. 35 ft. 30 ft. 20 ft. Capacity Models 3 35 ft. 25 ft. 20 ft. 15 ft. All Electric Dryers 4 25 ft. 15 ft. 15 ft. 10ft. 0 45 ft. 30 ft. 30 ft. 15 ft. Super & Ex
Electric Dryer Rating: 208/240V, 3-wire, 5600W, 60Hz, 30 Amp Installation Information: For complete information, see installation instructions packed with product for current dimensional data. R Listed by Underwriters Laboratories Specification Revised 10/99 NLL113EYWO - Hotpoint Dryer Exhausting Information— Best Performance Maximum Length of 4" Dia. Rigid Metal Duct Maximum Length of 4" Dia. Flexible Metal Duct Exhaust Hood Type Exhaust Hood Type Number of 90° Turns Domestic Dryer Models Cat.
Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12” above the ground or any other obstruction with the opening pointed Down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4” opening dampered wall cap. L
in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line. • No other fuel-burning appliance shall be installed in the same closet with the dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors. • The installation must conform with the local code
R Listed by Underwriters Laboratories Specification Created 7/99 NVL333GYWW - Hotpoint Dryer Exhausting Information— Best Performance Domestic Dryer Models B 2-1/2 A Maximum Length of 4" Maximum Length of 4" Dia. Rigid Metal Duct Dia. Flexible Metal Duct Exhaust Hood Type Exhaust Hood Type Number Cat. No. Cat. No. of WX8X59 WX8X59 B B 90° (Preferred) (Preferred) 2-1/2" 2-1/2" Turns A A Opening Opening 4" Opening 4" Opening Super & Extra-Large Capacity Models All Electric Dryers Super & Extra-Lar
Alternate exhausting knockouts are supplied. Circuit Requirements: An individual properly-grounded branch circuit, with a three-prong grounding-type receptacle, protected by a 15- or 20-amp circuit breaker or a time-delay fuse is required. Gas Dryer Electric Rating: 120V, 60Hz, 15 Amp Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply requires a conversion kit. Check installation instructions for correct kit and have a qualified gas technician install a conv
requirements for 0" spacing from walls below countertops. However some kitchen cabinet finishes can be damaged by heat from the range heating elements. It is recommended that a clearance of at least 1-1/2 inches be maintained to walls. Where varnished wood or plastic film finishes are used, a minimum clearance of 6 inches should be maintained. Receptacle Locations: Locally approved flexible service cord or conduit must be used because terminals are not accessible after range installation. See s
Ft. Super Capacity Electric Dryer Dryer Dimensions (in inches) Side View Rear View Exhaust Options: 4-way via rear, right, left and bottom. Circuit Requirements: An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a timedelay fuse, is required. Electric Dryer Rating: 208/240V, 3-wire, 5600W, 60Hz, 30 Amp Installation Information: For complete information, see installation instructions packed with product for current dimensional data. Best Performa
Circuit Requirements: An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required. Electric Dryer Rating: 208/240V, 3-wire, 5600W, 60Hz, 30 Amp Installation Information: For complete information, see installation instructions packed with product for current dimensional data. R Listed by Underwriters Laboratories Specification Revised 8/99 NVLR333EVWW—Hotpoint Dryer Exhausting Information—Use For complete information, see installationin
Ft. Super Capacity Electric Dryer Dryer Dimensions (in inches) 36 42 27 2 3-1/2 2-1/2 25-1/2* Side View Rear View 8-1/2 28-1/423-1/2 11-1/2 *24-1/2" from the edge of the side panel to the front. 25-1/2" from front to edge of endcaps. * 24-1/2” from the edge of the side panel to the front. 25-1/2” from front to edge of end caps. Exhaust Options: 4-way via rear, right, left and bottom. Circuit Requirements: An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a