Log:
Trier : Nom ↑   Téléchargements   Évaluation   Taille ↑  

Roberts Gorden DUAL AIR DAT100

Téléchargements : 39 Taille : 1 mb    Fabricant : Roberts Gorden  
Catégorie : électrique

Owner Keep this manual in a safe place in order to provide your serviceman with necessary information. Roberts-Gordon Europe Limited Unit A, Kings Hill Business Park Darlaston Road, Wednesbury West Midlands WS10 7SH UK Telephone: +44 (0)121 506 7700 Fax: +44 (0)121 506 7701 Service Telephone: +44 (0)190 249 8733 Service Fax: +44(0)190 240 1464 E-mail: uksales@rg-inc.com Quality in Any Language™ E-mail: export@rg-inc.com © Copyright 2007 Roberts-Gordon, LLC P/N X527 Rev C 10/07 TABLE OF CONTENTS

Roberts Gorden CRV-B-8

Téléchargements : 14 Taille : 2 mb    Fabricant : Roberts Gorden  
Catégorie : électrique

Failure to follow these instructions can result in death or electrical shock. WARNING Explosion Hazard Turn off gas supply to heater before service. Failure to follow these instructions can result in death, injury or property damage. There are several methods of controlling CRV-Series systems. The options are as follows: 8.1 ROBERTS GORDON® System Control (P/N 02770002) The ROBERTS GORDON® System Control is an electronic controller designed for the control of CORAYVAC® and VANTAGE® NP (multiburn

Roberts Gorden VANTAGE NP CTHN-60

Téléchargements : 11 Taille : 7 mb    Fabricant : Roberts Gorden  
Catégorie : électrique

Reflectors can be used over the manifold tube but are not required. The system design parameters are such that the manifold sections are not subjected to condensate when the system is fully heated up. It is required that heat-treated aluminized or coated tubing is used for the manifold to increase system life and to handle initial condensation during start-up. Damper couplings may be necessary to balance system vacuum. Design requirements for a CTHN multiburner system are summarized on Page 30,

Roberts Gorden Vantage TF TF-300

Téléchargements : 11 Taille : 5 mb    Fabricant : Roberts Gorden  
Catégorie : électrique

14 Figure 13: Linear Heater Assembly Overview ........................ 15 Figure 14: Linear Heater Layout Overview.............................. 16 Figure 15: Linear Heater Layout Overview (Continued) .......... 17 Figure 16: U-Tube Heater Assembly Overview ......................23 Figure 17: U-Tube Heater Layout Overviews .........................24 Figure 18: U-Tube Heater Layout Overviews (Continued).......25 Figure 19: Reflector Joint Detail..............................................27 Fi

Roberts Gorden EP-203

Téléchargements : 10 Taille : 2 mb    Fabricant : Roberts Gorden  
Catégorie : matériel de pompage

6.1 Prior to Operation Prior to operation of the pump in the heating system, operation and proper rotation of the impeller must be verified. IMPORTANT: Improper rotation of the impeller will not produce the vacuum required for proper system operation. The EP-201 motor must be wired for clockwise or counterclockwise rotation as shown on Page 12, Figure 11. The EP-201 motor is wired for 1 O, 120 V, 60 Hz operation. The EP-201 motor can be rewired for 230 V operation by changing the motor connectio

Roberts Gorden EP-200 Series

Téléchargements : 9 Taille : 2 mb    Fabricant : Roberts Gorden  
Catégorie : matériel de pompage

. . . . . . . . . . . !". . . Roberts-Gordon Roberts-Gordon 1250 William Street 76 Main Street West, Unit 10 P.O. Box 44 Grimsby, Ontario, L3M 1R6 Buffalo, New York 14240-0044 Canada Telephone: 716.852.4400 Telephone: 905.945.5403 Fax: 716.852.0854 Fax: 905.945.0511 Toll Free: 800.828.7450 Quality in Any Language™ © Copyright 2004 Roberts-Gordon P/N 127200NA Rev. F 12/04 TABLE OF CONTENTS SECTION 1: Heating System S

Roberts Gorden Combat UHD[S] 75 - 125

Téléchargements : 7 Taille : 631 kb    Fabricant : Roberts Gorden  
Catégorie : électrique

Install downstream of refrigeration system with ¦¦ option stainless steel heat exchangers and drain pan (Models UHD[S] 150-400 only). 1.800.828.7450 Quality in Any LanguageTM Combat® UHD[S] 75 - UHD[S] 125 Clearances and Dimension Data Clearances to Combustibles - Low Profile UHD[S] Range (Models 75 - 125) Above Heater Below Heater To Side of Heater Access Side Door To Flue 1" 1" 1" 18" Access Clearance 2" Dimension Data - Low-Profile UHD[S] Range (Models 75 - 125) Model 75 100 125 'A' Height [i

Roberts Gorden CRV-B-2

Téléchargements : 7 Taille : 2 mb    Fabricant : Roberts Gorden  
Catégorie : électrique

Roberts-Gordon LLC 1250 William Street P.O. Box 44 Buffalo, New York 14240-0044 Telephone: 716.852.4400 Fax: 716.852.0854 Toll Free: 800.828.7450 © 2009 Roberts-Gordon LLC P/N 127500NA Rev D 05/09 TABLE OF CONTENTS SECTION 1: Concept ..............................................................1 SECTION 2: The CRV-Series System.....................................2 2.1 Safety...........................................................................2 2.2 Zero Regulator..........................

Roberts Gorden VANTAGE NP CTHN-40

Téléchargements : 5 Taille : 7 mb    Fabricant : Roberts Gorden  
Catégorie : électrique

CTHN-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL 22 Step 8.9 Reflector Installation Description Part Number Tube/Reflector Hanger 03090100 Burner Tube 03051XXX Reflector 02750303 NOTE: All radiant tube surfaces must be covered by a reflector, except for a u-tube. Manifold tube may or may not be covered. SECTION 8: UNITARY LINEAR & U-TUBE HEATER INSTALLATION 23 Step 8.9.1 Reflector, U-clip and Reflector Support Installation The pictorial drawings of the heater construction in Section 8

Roberts Gorden Combat UHA 30 - 125

Téléchargements : 4 Taille : 504 kb    Fabricant : Roberts Gorden  
Catégorie : électrique

LPG Propane Min. 5 - All Models 12 - All Models NG & LP Propane Max. 14 - All Models Electrical Supply 115 V / 60 Hz / 1 0 - All Models Full Load Amps @ 115 V 3.0 3.0 4.1 4.1 5.8 5.8 7.1 7.1 10.6 10.6 10.6 11.6 11.6 11.6 Air Volume [CFM] 691 691 1376 1376 1902 1902 2245 2245 3716 3716 3716 4663 4663 4663 Recommended Maximum Mounting Height [ft] 12 12 15 15 20 20 20 20 25 25 25 30 30 30 Number of Axial Fans 1 1 1 1 1 1 1 1 1 1 1 2 2 2 Axial Fan Diameter





catégories