Log:
Trier : Nom ↑   Téléchargements   Évaluation   Taille ↑  

NuTone 696N

Téléchargements : 27 Taille : 344 kb    Fabricant : NuTone  
Catégorie : Ventilateurs

Connect white supply wire to white wire of receptacle. Connect supply ground wire to green or uninsulated wire of receptacle. Push all wiring up into corner of unit and replace wiring cover. Make sure cover holds housing flap in place against side or top of housing. CAUTION: DO NOT ALLOW WIRES TO EXTEND OUTSIDE OF WIRING BOX. Wire left exposed will become pinched or cut when motor plate is installed. Electrical shock may result. (FIG. 3) 4. Choose the location for your fan. For best performance,

NuTone 755NT

Téléchargements : 14 Taille : 105 kb    Fabricant : NuTone  
Catégorie : Ventilateurs

Bulbs not included. • Vent openings in fixture base for exhaust fan • Light fixture assembly is plug-in and removable BLOWER: • Plug-in permanently lubricated motor • Polymeric blower wheel HOUSING: • Rugged, 26-gage galvanized steel construction • Sturdy key-holed mounting brackets for quick, accurate installation • Tapered, polymeric duct fitting with built-in backdraft damper for easy, positive duct connection and no metallic clatter NOTE: For installation in flat ceilings only. U.L.

NuTone AVD50N

Téléchargements : 11 Taille : 663 kb    Fabricant : NuTone  
Catégorie : Fers

24” on-center studs will require framing to proper opening size. 2. DETERMINE DISTANCE ABOVE THE FLOOR. Use the following chart to determine the recommended wall opening above the floor: Wall Opening Working Height Above the Floor AVD40/45 Series AVD50 Series 24” 30” 29”-30.”-32.” 28” 34” 33”-34.”-36.” 30” 36” 35”-36.”-38.” 32” 38” 37”-38.”-40.” 3. ATTACH CLEATS. Fasten 2x4 cleats to wall studs to provide a level surface on which to rest cabinet. 4. MOUNT CABINET. Lift cabinet into place and att

NuTone NP503004

Téléchargements : 11 Taille : 1 mb    Fabricant : NuTone  
Catégorie : Ventilateurs

D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA. 2 !! CAUTION 1. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 2. Take care when using cleaning agents or detergents. 3. Avoid using food products that produce flames under the Range Hood. 4. For general ventilating use only. Do not use to exhaust hazar

NuTone 9960

Téléchargements : 11 Taille : 395 kb    Fabricant : NuTone  
Catégorie : matériel de pompage

2. Total connected load: 1680 watts. 3. Plan to run 120vAC, 60 Hz wiring (with ground) on a separate 20 Amp circuit from a power source, through the provided wall switch, to the housing’s junction box. See wiring diagram. INSTALLATION IN NEW CONSTRUCTION PREPARATION 1. Loosen hanger bar brackets to allow bars to be inserted. 2. Refer to Figure 2. Insert hanger bars into brackets. 3. Refer to Figure 3. Slide hanger bar brackets down to end of slot closest to outside edge of housing. Tighten brack

NuTone 9192NT

Téléchargements : 9 Taille : 128 kb    Fabricant : NuTone  
Catégorie : Climatiseurs

All electrical work must be done in accordance with local or national electrical code as applicable. For safety, this product must be grounded. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified electrician. 2. When wiring, servicing or cleaning this unit, turn off power and lock out service panel. Failure to do so could allow others or thermostat to turn on power unexpectedly which may cause fatal electrical shock. 3. To avoid electrical shock

NuTone 8832SA

Téléchargements : 9 Taille : 469 kb    Fabricant : NuTone  
Catégorie : Ventilateurs

Loosely attach housing to ceiling joists through keyhole slots in mounting brackets. Keyhole slots in brackets are provided INSTALLATION IN A NEW to allow for adjustment to various ceiling thicknesses. AdjustCONSTRUCTION SITE housing so bottom is flush to proposed finished plaster line, then securely fasten housing to joists. 1. Remove the blower unit from the housing by unplugging it then loosening the three mounting screws and rotating the unit to free it from the screws. INSTALLATION IN A NEW

NuTone 8832WH

Téléchargements : 9 Taille : 469 kb    Fabricant : NuTone  
Catégorie : Ventilateurs

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D. Ducted fans must always be vented to the outdoors. E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application. F. NEVER place a switch where it can be reached from a tub or shower. G. Do not use this fan with any solid-state speed control device. FOR BEST RESULTS When installing the ventilator in a new construction site, install the h

NuTone 605RP

Téléchargements : 8 Taille : 419 kb    Fabricant : NuTone  
Catégorie : Climatiseurs

Use them individually or together. 1) 1500W heating element provides fast enveloping heat. Efficient fan evenly distributes warm air through room. 2) Exhausts stale air and moisture to refresh the bath atmosphere. • Streamline design with handsome white grille. Grille is tough polymeric, impervious to bathroom climate. • Includes adjustable hanger bars. 16"-24". Built-in junction box with receptacles for simple plug-in of heater and fan motors. • Nickel-chrome heating element. • Quiet poly

NuTone NM200AL

Téléchargements : 7 Taille : 491 kb    Fabricant : NuTone  
Catégorie : Téléphones filaires

Mount each remote station to its mounting ring using the two screws provided with each NM200 remote station CONNECTING THE IA30WH Audio Wall plate Use the labels provided to mark respective cables. Connect the cables to the IA30WH audio wall plate and mount the plate using the two screws provided. Please see figure below and refer to the NuTone IA30WH installation guide for more detailed instructions. installing the Door Stations At each door station location, strip approximately 4 inches of jac