Log:

Omega Engineering OM8800D

Téléchargements : 5 Taille : 7 mb    Fabricant : Omega Engineering  
Catégorie : Station météorologique

2 Features.................................................................................... 3 Front View ................................................................................ 4 LCD display (Model OM8828 / Om8829)....................................................... 5 Battery replacement.................................................................. 6 Software Installation ................................................................. 7 Main screen & introduction............

Omega Engineering OM8829

Téléchargements : 5 Taille : 7 mb    Fabricant : Omega Engineering  
Catégorie : Station météorologique

(See Diagram I-1 ) 27 Temperature/Humidity Logger Monitor PREVIOUS SETTING: ID= File name:d\TRLog\TempRhEx1.txt DATE(M-D-Y) 11-23-2001 TIME 17:12:57 86.0 100 88.0 70.0 80 60.0 Diagram J 90 70 60 50 40 10.0 30 0.0 20 -10.0 10 -23.0 0 0001 0401 0801 1201 1601 2001 2401 2801 3201 3601 4000 4400 4800 5200 5600 6000 6400 6800 7200 7600 8000 08-03-2001 14:46:05 TEMPERATURE/HUMIDITY CHART Record No Time 08-03-2001 19:12:43 CURSOR LOCATION Cursor 1: # 2530 T=64.7 RH=10.1 Date(M-D-Y)=08-03-2001 Time=16:1

Omega Engineering OM88128

Téléchargements : 3 Taille : 7 mb    Fabricant : Omega Engineering  
Catégorie : Station météorologique

c).Brow CD-ROM. Browse the CD-Rom using Windows. d).Web Site. Visit our web site in your browser. e).Exit. Close this menu system. OM8818 OM8828 OM8829 OM88128 7 MAIN SCREEN The data logger program is easy to operate from its main screen. Data Com. Set Print Close Maximize Table Graph Minimize Program Save Retrieve File Logger GroupFile Set Statistics Files Logo Previous Setting 100.0 90.0 Cursor 1 80.0 (red) 70.0 60.0 50.0 Temperature %Rh Humidity Chart 40.0 Chart 30.0 Cursor 2 20.0(green) 10.0

Omega Engineering OM8828

Téléchargements : 5 Taille : 7 mb    Fabricant : Omega Engineering  
Catégorie : Station météorologique

If a Temperature is higher than HI setting or less than LO setting , ALM LED will flash every second until you download to a PC . For models OM88128, OM8828 ,OM8829 , if a temperature is higher than HI setting or less than LO setting , ALM LED will flash per every sample interval , for example , if set to 3 seconds for an interval , ALM and REC LED will flash every 3 seconds until you download to a PC . 18 UNIT SETTING Data logger is available in "oC" and "oF" (See Diagram G) as well as oo Humid

Omega Engineering LVRD500

Téléchargements : 4 Taille : 3 mb    Fabricant : Omega Engineering  
Catégorie : Autres outils

Push button and hold until LED goes OFF after the sequence of Yellow , Red and turns Off. The Low Dielectric Material operation is On when the LED’S Green light blinks constantly. 2) To turn the Low Dielectric Materials OFF. Push button and hold until LED goes OFF after the sequence of Yellow , Red and Turns OFF. The Low Dielectric Material operation is OFF when LED is continuously Green. Operation - An ultrasonic/electromagnetic pulse is transmitted from the sensor . The pulse travels to the su

Omega Engineering LVU40

Téléchargements : 0 Taille : 3 mb    Fabricant : Omega Engineering  
Catégorie : Autres outils

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. WARNING-Changes or Modifications not expressly approved by the Manufacturer could void the user’s authority to operate th

Omega Engineering CDE-45P

Téléchargements : 5 Taille : 2 mb    Fabricant : Omega Engineering  
Catégorie : Autres outils

3 1.2 Sensor Features....................................................................................................................................... 3 1.3 Sensor Specifications (CDE-45P)............................................................................................................ 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)............................................................ 4 PART 2 – INSTALLATION.............................................

Omega Engineering DP-F30

Téléchargements : 7 Taille : 2 mb    Fabricant : Omega Engineering  
Catégorie : Calculatrices

Mm ENGINEERING. INC. Ill fMII.'i»' I /¿'r/imi/ot’irs 4 M1091/1289 99504 WARRANTY OMEGA warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that our customers receive maximum coverage on each product. If the unit should malfunction, it must b

Omega Engineering DP1632

Téléchargements : 1 Taille : 1 mb    Fabricant : Omega Engineering  
Catégorie : Station météorologique

OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.

Omega Engineering RG-2500

Téléchargements : 4 Taille : 941 kb    Fabricant : Omega Engineering  
Catégorie : Station météorologique

When you receive the shipment, inspect the container and equipment for signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent. The carrier will not honor damage claims unless all shipping material is saved for inspection. After examining and removing contents, save packing material and carton in the event reshipment is necessary. Y TABLE OF CONTENTS Chapter 1 Introduction ......................................... 1 . 1.1 General Descr





catégories