0dB INPUT: Connect your “passive” bass guitar here using a shielded instrument cable. This input is not padded and is best suited for basses without active electronics or “hot” pickups. 2. -15dB INPUT: Connect your “active” bass here using a shielded instrument cable. This input is padded 15dB and is best suited for basses with active electronics and/or “hot” pickups. 3. VOLUME: Use this control in conjunction with your instrument’s volume controls to adjust the output level of the amplifier. Th
• Always keep the total speaker impedance at or above the rated load. • Unplug the amplifier before cleaning it. NEVER spray liquid cleaners onto the amplifier. Wipe it with a slightly dampened, lint-free cloth to remove dirt and film. • Do not use the amplifier if it has sustained damage to the chassis, controls, or power cord. Refer the unit to an authorized service center for inspection. • Amplifiers capable of producing high volume levels are also capable of inflicting permanent hearing loss
by V-50H Guitar Amplifier Thank you for choosing Ampeg. In order to obtain the best performance from your new amplifier we recommend you review the information in this owner’s guide prior to its use. 12 3 THE FRONT PANEL: 1. Power switch is used to turn the amplifier on and off. 2. Power light indicates the amplifier is turned on by glowing an iridescent blue color. 3. Reverb controls the amount of reverberation applied to the signal. With the control at the “0” position there is no reverb appli
0dBINPUT:Connect your “passive” bass guitar here using a shielded instru- ment cable. This input is not padded andis best suited for basses without activeelectronics or “hot” pickups. 2. -15dBINPUT: Connect your “active” bass here using a shielded instrumentcable. This input is padded 15dB and isbest suited for basses with active elec- tronics and/or “hot” pickups. 3. GAIN: Use this control in conjunctionwith your instrument’s volume controls toadjust the level of the signal sent to thepreamp. 4
by TABLE OF CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Important Safeguards and Precautions . . . . . . . . . .3 The Front Panel Controls and Their Use . . . . . . . .4 The Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Some Suggested Settings . . . . . . . . . . . . . . . . . . .6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . .7 System Block
INTERNE TEILE KONNEN NICHT VOM BENUTZER GEWARTET WERDEN. DIE WARTUNG IS QUALIFIZIERTEM WARTUNGSPERSONAL ZU UBERLASSEN. THIS EQUIPMENT HAS BEEN DESIGNED AND ENGINEERED TO PROVIDE SAFE AND RELIABLE OPERATION. IN ORDER TO PROLONG THE LIFE OF THE UNIT AND PREVENT ACCIDEN- TAL DAMAGES OR INJURY, PLEASE FOLLOW THESE PRECAUTIONARY GUIDELINES: WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT OPEN CHASSIS; DO NOT DEFEAT OR REMOVE THE GROUND PIN OF THE POWER CORD; CONNECT ONLY TO A PROP- ERLY GROUNDE
INPUT: The signal output from an instrument (active or passive) or a line level signal may be connected here by means of a shielded instrument cable. 2. -15dB PAD: This switch, when depressed, attenuates the input signal by 15dB. Attenuation allows the Gain control (#4) to be used in a more usable (higher) position. If clipping is indicated with the Gain control at a low setting, attenuation is needed. 3. PEAK LED: This LED flashes when the signal level into the preamp approaches clipping. Adjus
Attenuation allows the Gain control (#4) to be used in a more usable (higher) position. If clipping is indicated with the Gain control at a low setting, attenuation is needed. 3. PEAK LED: This LED flashes when the signal level into the preamp approaches clipping. Adjust the Gain control (#4) until a strong signal from your instrument causes this LED to flicker. NOTE: If the LED flashes frequently with the Gain at a low setting, use the -15dB pad (#2) to attenuate the input signal and readjust t
For full range, wire the Speakon® connectors as follows: Pin 1+ : Full Range positive (+) Pin 1– : Full Range negative (–) BI-AMP OPERATION: • Set the Mode switch to the “Biamp" position. • Set the crossover point for the amplifiers somewhere in the 100Hz to 300Hz range. Once up and running, adjustments within this range may be made to suit your personal listening palate. • 1/4” JACKS: Connect the output of your low frequency amplifier to either of the two 1/4” jacks labeled “Full Range Inputs (
Outstanding sound and legendary Ampeg performance have been embodied in rugged, stylish cabinets which are incredibly road-worthy and surprisingly manageable. The PR-1832HE is a four-way full range bass speaker system inspired by Victor Wooten. This enclosure packs the punch of traditional 2-10 / 4-10 cabinets, but with the added advantage of the built-in 18" subwoofer. This enclosure is designed for high SPL and low distortion. The frequency response is smooth and accurate all the way down to 3