Acorn Nuts Weld Screws Figure 9. Replacing Spring Tensioner Assy. 4. Make sure the spacers are placed inside the tensioner arm. The spacers are smaller than the holes to allow the tensioner to pivot freely. Replacing Conveyor Motor and Fan Blade NOTE: A small amount of Loctite (Blue & Red) is required for proper gear motor installation. 1. Remove control cover. 2. Disconnect the motor wires and remove the drive motor and drive motor bracket (Figure 10). Discard the 8-32 x 5/16” mounting bracket
To reset this thermostat, allow sufficient time (10-15 minutes) for the unit to cool down, then fully depress the reset button located at the rear of the unit (Figure 5). If the unit requires continuous resetting, contact your Roundup authorized service agency. CONVEYOR INTERLOCK SWITCH A conveyor interlock switch is located on top of the unit under the heat shield (Figure 4). The conveyors will not rotate unless the heat shield is in place and interlock switch is activated (depressed). Bun Thic
Monthly Your Miracle Steamer utilizes an open steam generator. Water sprayed onto the generator surface flashes into steam immediately, but the minerals in the water do not steam, they stay on the generator surface. A small amount of mineral deposits are needed for proper operation, but a build-up of excessive mineral deposits causes poor steaming efficiency, excessive moisture (wet steam) and will eventually severely retard the steaming action completely. Cleaning Steam Generator 1. Turn the ro
to clear/reset this record, press both the uP and DOWN arrow buttons simultaneously (before turning the unit Off) and the display will show 33°f - indicating that record has been cleared - and then turn the unit Off. P/N 1010745 Rev. g 03/06 17 Variety Steamer maIntenance (continued) technical theory of Operation When the Rocker switch (power On/Off) is ON, line voltage flows to the primary side of the step down transformer. the transformer’s secondary side supplies 12 and 24 Vac to the control
D 08/05 13 EGG STATION (ES-600 & ES-1200) 14 P/N 1010871 Rev. D 08/05 REPLACEMENT PARTS 18 21 11 3 27 14 18 31 13 28 65 16 25 51 53 59 61 60 24 19 5 55 4 58 14a 27 31 13a 28 65 45 45 48 48 66 54 63 52 62 57 56 69 2 7 26 29 15 1 12a 12 64 EGG STATION (ES-600 & ES-1200) REPLACEMENT PARTS (continued) Item Part Description Qty. Item Part Description Qty. No.No. 1 0021327 Nose Piece Weldment 1 42 308P143* Nut, Hex KEPS #8-32 1 2 210K230 Bumper, Recess Leg 1” 1 43 308P157* Screw, Tap #8-32 x 3/8” 1 (S
Nickel. MAINTENANCE (continued) Replacing the Optional Roller Tensioners 1. Remove the acorn nuts and old roller Tensioner Assembly (Figure 12). 2. Replace Tensioner Assembly, and reassemble. 3. Make sure the spacers are placed inside the Tensioner arm. The spacers are smaller than the holes to allow the Tensioner to pivot freely. Weld Screws Acorn Nuts Tensioner Assy. Spacers Teflon Tape Figure 12. Replacing Roller Tensioner Assy. Figure 14. Measuring Roller Tensioner Replacing the Spring Tensi
CAUTION Chlorides or phosphates in cleansing agents (e.g. bleach, sanitizers, degreasers or detergents) could cause permanent damage to stainless steel equipment. The damage is usually in the form of discoloration, dulling of metal surface finish, pits, voids, holes or cracks. This damage is permanent and not covered by warranty. The following tips are recommended for maintenance of your stainless steel equipment: • Always use soft, damp cloth for cleaning, rinse with clear water and wipe dry. W
If low or zero voltage, replace power cord. If voltage is correct, check for correct voltage out of rocker switch. If low or no voltage, replace rocker switch. Wiring problem. Check all electrical connections for burns, discoloration or arcing. Replace all connections or components with damaged terminals. Replace all damaged wiring with the same (or higher) rated wire. Platen inoperative. To check platen: Use an Ohm meter to test resistance of the platen heater (disconnect 1 wire to isolate heat
Steam coming out around top covers or sides. Generator Cover’s wingnut is loose. Tighten wingnut. Generator Cover is warped. Replace Generator Cover. 20 P/N 1010699 Rev. M 12/06 MIRACLE STEAMER TROUBLESHOOTING (continued) Problem Possible Cause Corrective Action Unit floods overnight and/or continues to steam even when in idle mode. Solenoid Valve is leaking due to debris trapped inside the plunger (MS-250/255). Attempt to flush the debris out of the valve by rapidly operating the unit on a numb
D 08/05 Owner’s Manual EGG STATION (ES-600 & ES-1200) TABLE OF CONTENTS Owner Information .....................................................2 General ......................................................................2 Warranty Information .................................................2 Service/Technical Assistance ....................................3 Important Safety Information ....................................3 Electrical Ratings ..................................................