Log:

Monessen Hearth WINSLOW PI40

Téléchargements : 1 Taille : 2 mb    Fabricant : Monessen Hearth  
Catégorie : Cheminées

Order P/N 775,229CF. USPortland Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numero de la piece 775,229CF. Report No. 050-S-14b-2 These appliances must be properly installed and operated in order to prevent the possibility of a house fire. Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death. Contact your local bu

Monessen Hearth VF6000-CMP-2

Téléchargements : 0 Taille : 1007 kb    Fabricant : Monessen Hearth  
Catégorie : Cheminées

The appliance is shipped with all gas controls and components installed and pre-wired. Remove the shipping carton, exposing the optional (if installed) front glass door frame. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. Remove wood slats and remove and discard the wood slat mount brackets. Loosen and remove the three (3) 1/4"-20 x 1" Phillips pan head screws at the three (3) tabs located along the door frame top edge. Tilt the glass door frame assembly outward and disengage the three (3) tabs al

Monessen Hearth VF6000-CMN-2

Téléchargements : 2 Taille : 1007 kb    Fabricant : Monessen Hearth  
Catégorie : Cheminées

The gas control valve is located in the lower control compartment. To access the valve open the lower control compartment door (Figure 12). The control valve has a 3/8" NPT thread inlet port and is fitted with a 3" (76 mm) long nipple, 3/8" NPT on both ends. Plan the connections accordingly. We recom- mend that the gas line be routed for the left side of the appliance to ensure adequate ac- cess to the rear lower compartment for instal- lation and servicing of the optional FAB-1100 blower. Secur

Monessen Hearth VF5000-CMP-2

Téléchargements : 7 Taille : 1007 kb    Fabricant : Monessen Hearth  
Catégorie : Cheminées

2. These heater rated units are equipped with a two stage (HI, LOW) gas control valve. To cycle the burner between the HI and LOW settings, rotate the control knob, located in the center of the valve front face, clockwise and counterclockwise respectively. 3. When lit for the first time, the appliance will emit a slight odor for an hour or two. This is due to the “burn-in” of the internal paints and lubricants used in the manufacturing process. Additionally, when lit for the first time, this app

Monessen Hearth VF5000-CMN-2

Téléchargements : 3 Taille : 1007 kb    Fabricant : Monessen Hearth  
Catégorie : Cheminées

Refer to Figure 16 for floor and platform installations. If the heater is to be installed into a framed wall refer to the built-in assembly steps beginning on page 4. Note:The heater may be installed directly on a floor made of standard combustible wood construction materials. Do not install the heater directly on carpeting or other soft floor covering such as vinyl tile or flooring materials. Use a wood or metal panel that extends the full width and depth of the heater between the heater and an

Monessen Hearth VF4000-CMP-2

Téléchargements : 4 Taille : 1 mb    Fabricant : Monessen Hearth  
Catégorie : Cheminées

• The installation must conform with local codes or, in the absence of local codes with the National Fuel Gas Code, ANSI Z223.1. • The heater and its individual shut-off valve must be disconnected from the gas supply piping system while performing any tests of the gas supply piping system at pressures in excess of 1/2 psig. • The heater must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at

Monessen Hearth VF4000-CMN-2

Téléchargements : 1 Taille : 1 mb    Fabricant : Monessen Hearth  
Catégorie : Cheminées

Unusually tight construction is defined as construction where: a. wall and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating or one perm or less with openings gasketed or sealed, and b. weather stripping has been added on operable windows and doors, and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall- ceiling joints, between wall panels, at penetrations for plumbi

Monessen Hearth VF4000-CHP-2

Téléchargements : 0 Taille : 1 mb    Fabricant : Monessen Hearth  
Catégorie : Cheminées

In addition a periodic visual check of the flames should be made. The pilot flame should always be present when the heater is in operation and should just envelope the tip of the thermocouple (Figure 15). WARNING: NO ADJUSTMENTS ARE TOBE MADE TO THE ODS PILOT SYSTEM. TAMPERING WITH THIS SYSTEM CANBE EXTREMELY HAZARDOUS. Standard (Manual) Version Shown Figure 15 An incorrect pilot flame is shown inFigure 16. This pilot flame will cause the thermocouple to cool. When the thermocouple cools, the he

Monessen Hearth VF4000-CHN-2

Téléchargements : 1 Taille : 1 mb    Fabricant : Monessen Hearth  
Catégorie : Cheminées

WHAT TO DO IF YOU SMELL GAS • Donottrytolightanyappliance. • Donottouchanyelectricalswitch;donotuseany phone in your building. • Immediatelycallyourgassupplierfromaneighbor’sphone.Followthegassupplier'sinstructions. • Ifyoucannotreachyourgassupplier,callthe fire department. Installation and service must be performed by aqualifiedinstaller,serviceagencyorthegassupplier. WARNING: If the information in this manual is notfollowedexactly,afireorexplosionmayresultcausingpropertydamage,personalinjuryor

Monessen Hearth UVFRC-4228-H

Téléchargements : 0 Taille : 1 mb    Fabricant : Monessen Hearth  
Catégorie : Cheminées

The appliance may be located on or near conventional construction materials. However, if installed on combustible materials, such as carpeting, vinyl tile, etc., a metal or wood barrier covering the entire bottom surface must be used. NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. ASSEMBLY STEPS Notes: • Illustrations shown in this manual reflect “typical” installations with nominal dimensions and are for design and framing reference only. Actual installations may vary due to individual design