If using 6'' (150 mm) round ducts, use a transition. Use 2'' (50 mm) metal foil duct tape to seal joints. 2. MEASURE THE INSTALLATION Dimensions for the most common installations are shown below. We recommend to install the hood at a minimum of 20” (508 mm) from an electric range and at 24” (610 mm) from a gas range. For optimal performance, the hood should not be installed more than 30” (762 mm) from cooktop. - 4 - 3. PREPARE THE INSTALLATION Make sure the following items are included:
Then, slide in the diffuser (2). See illustration beside. VD0158 - 12 6.1 MAIN SWITCH All units are equipped with a 3-position main switch, located on the front panel. 6.2 40415 AND 40425 WALL CONTROLS DESCRIPTION The included wall control is 40415 (intented for HRV 2600, HEPA 3100 and HEPA 4100 units only) or 40425 control (intented for HR 2.6 and HF 3.1 units only). The wall control is in OFF mode when power is applied for the first time. The mode does not change following a power failure. 404
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 6.2 40415 AND40425 WALLCONTROLS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 6.3 OPERATING 40415 / 40425 CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 6.4 WALLCONTROLS CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
READ AND SAVE THESE INSTRUCTIONS 04313 rev. G M O D E L S ABOUT THIS MANUAL First, we want to congratulate you on your purchase of this excellent unit which will allow you and your family to enjoy clean and healthy air throughout your home for years to come! Because of the large amount of models covered by this publication, the illustrations are typical ones. Some details of your unit may be slightly different than the ones shown. Please take note that this manual uses the following symbols to e
Wipe completely dry. • You may also use a specialized household stainless steel cleaner. Don’t: • Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt. • Use any harsh or abrasive cleansers. • Allow dirt to accumulate. • Let plaster dust or any other construction residues reach the hood. During construction or renovation, cover the hood to make sure no dust adheres to stainless steel surface. Avoid: when choosing a detergent - Any cleaners that contain blea
HOMEOWNER: CLEANING AND OPERATION INFORMATION ON PAGES 9 AND 10. REGISTER YOUR PRODUCT ON LINE AT: ENERGY STAR SV06727 rev. D /t WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service disco
VK0003F 12.00"[305] Couvercle duboitier PTSVRC 1200i NOYAU POLYavec module recirc. VRC 1200i NOYAU ALUavec module recirc. LBS247 Kg112 PTSTOTAL LBS269 122Kg TOTAL NOTES: Dimensions in [ ] are in millimeters Appendix B Continued Unit Dimensions B-5: 700 cfm Page 14 HRV700iLBS Kg 32.74 14.85 68.46 31.05 35.20 15.97 73.60 33.38 210.00 ABCDTOTAL 95.25PTS 14 gauge wire nutCondensate drain fitting (2x) AB 3/4" mpt CONNECTION TABLECONNECTION SIZES 10.000"[254] Center of gravityDirection of airflow1.875
The connection from the ventilator to the control is low voltage and requires a 4 conductor (24 ga. minimum) LVT cable. Models are available with either a dehumidistat control or gas sensor. The following four options are available. Slide Switch Type Dehumidistat to engage high speed exchange. Slide switch operation supporting continuous low exchange and continuous high exchange. Push Button Electronic Type Dehumidistat to engage high speed exchange. Push-button operation supporting: intermitten
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2 Installation 2.1 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2.2 Mounting Location Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2.3 Mounting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2.4 Ductwork . . . . . . . . . . . . . . . . . .