Log:

TriStar SP3215X20

Téléchargements : 9 Taille : 314 kb    Fabricant : TriStar  
Catégorie : matériel de pompage

To original purchasers of this pump, Hayward Pool Products, Inc., 620 Division Street, Elizabeth, New Jersey, warrants its products free from defects in materials and workmanship for a period of ONE (1) year from the date of purchase. Parts which fail or become defective during the warranty period, except as a result of freezing, negligence, improper installation, use, or care, shall be repaired or replaced, at our option, without charge, within 90 days of the receipt of defective product, barri

TriStar SP3210X15

Téléchargements : 4 Taille : 314 kb    Fabricant : TriStar  
Catégorie : matériel de pompage

The “thermal overload protector” will allow the motor to automatically restart once the motor has cooled. It will continue to cut On/Off until the problem is corrected. Be sure to correct cause of overheating. Motor Hums, But Does NOT Start – Check For: 1. Impeller jammed with debris. Solution: Have a qualified repair professional open the pump and remove the debris. Pump Won't Prime, Check For: 1. Empty pump/strainer housing. Solution: Make sure pump/strainer housing is filled with water and co

TriStar SP3210EE

Téléchargements : 21 Taille : 314 kb    Fabricant : TriStar  
Catégorie : matériel de pompage

No. Part No. Description Ctn. Qty. 12 SPX3205C Impeller for . HP with Impeller Screw 10 SPX3207C Impeller for . HP with Impeller Screw 10 SPX3207CM Impeller for 1 HP with Impeller Screw (Max Rate) 10 SPX3210C Impeller for 1 HP with Impeller Screw (Full Rate) 10 SPX3215C Impeller for 1 . HP with Impeller Screw 10 SPX3220C Impeller for 2 HP with Impeller Screw 10 SPX3230C Impeller for 3 HP with Impeller Screw 10 13 SPX3200SA Shaft Seal Assembly 10 14 SPX3200T Housing O-Ring 10 15 SPX3200E Seal Pla

TriStar SP3207X10

Téléchargements : 5 Taille : 314 kb    Fabricant : TriStar  
Catégorie : matériel de pompage

Remove the two diffuser screws (item #7), and pull the diffuser (item #9) off of the seal plate (item #15) to expose the impeller (item #12). WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar™ Pump Series ___________________ ______________________________ Page 10 of 15 Removing the Impeller (See Parts Diagram on page 11 of this manual for pump component locations.) 3. Remove the motor canopy by removing the two (2) screws and pulling the canopy away from the motor. 4. To pre

TriStar SP3207EE

Téléchargements : 6 Taille : 314 kb    Fabricant : TriStar  
Catégorie : matériel de pompage

NOTE - Tighten strainer cover lock ring by hand only (no wrenches). Before re-starting pump, see “Starting/Priming the Pump” instructions. ATTENTION – Wait five (5) seconds before re-starting pump. Failure to do so may cause reverse rotation of motor and consequent serious pump damage. Turn on power and wait for pump to prime, which may take up to five (5) minutes. Priming time will depend on vertical length of suction lift and horizontal length of suction pipe. If pump does NOT prime within fiv

TriStar SP3015X20AZ

Téléchargements : 6 Taille : 314 kb    Fabricant : TriStar  
Catégorie : matériel de pompage

Reference NEC codes for all wiring standards including, but not limited to, grounding, bonding and general wiring procedures. Use a solid copper conductor, size 8 or larger. Run wire from external bonding lug to reinforcing rod or mesh. Connect a No. 8 AWG (8.4 mm2) solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool, spa, or hot tub, and to all electrical equipment, metal piping (except gas piping), and conduit within 5

TriStar SP3015EEAZ

Téléchargements : 6 Taille : 314 kb    Fabricant : TriStar  
Catégorie : matériel de pompage

If leaks occur, remove connector, clean off old Teflon tape, re-wrap with one to two additional layers of Teflon tape, and re-install connector. Fittings restrict flow. For better efficiency, use the fewest possible fittings (but at least two suction outlets). Avoid fittings that could cause an air trap. Pool and spa fittings MUST conform to the International Association of Plumbing and Mechanical Officials (IAPMO) standards. Use a non-entrapping suction fitting in pool (multiple drains) or doub

TriStar SP3010X15AZ

Téléchargements : 9 Taille : 314 kb    Fabricant : TriStar  
Catégorie : matériel de pompage

TriStar has a variety of bases available to seamlessly retrofit to existing filtration systems. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar™ Pump Series__________ _____ ______________________________ Page 5 of 15 Product Specifications HP FR “A” MR “A” . 13 5/8” - . 13 7/8” 13 3/8” 1 14 3/8” 13 7/8” 1 * 14 3/8” - 1 . 14 7/8” 13 7/8” 1 . * 14 7/8” 14 3/8” 2 14 7/8” 15 1/8” 2 * 14 7/8” 14 7/8” 2 . -14 7/8” 2 . * -14 7/8” 3 17 1/8” 15 5/8” 3 ** 14 1/2” - * Two-Speed Pump

TriStar SP3010EEAZ

Téléchargements : 11 Taille : 314 kb    Fabricant : TriStar  
Catégorie : matériel de pompage

- Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user. - Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. - The maximum system flow rate shall not exceed the values shown in the “Pipe Sizing Chart” found at the bottom of page 5 of this manual. - Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. - Replace damaged, broken, cr

TriStar SP3007X10AZ

Téléchargements : 7 Taille : 314 kb    Fabricant : TriStar  
Catégorie : matériel de pompage

It requires free circulation of air for cooling. Do not install in a damp or non-ventilated location. If installed within an outer enclosure or beneath the skirt of a hot tub or spa, adequate ventilation and free circulation of air must be provided to prevent overheating of the motor. WARNING – Pool and spa components have a finite life. All components should be inspected frequently and replaced at least every ten years, or if found to be damaged, broken, cracked, missing, or not securely attach





catégories