Set the thermostat mode to “OFF” prior to changingsettings in setup or restoring Factory Defaults. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 4Z95 Thermostat TSTATG2111 Tested to Comply with FCC Standards FOR HOME OR OFFICE USE FCc Page i How to Use This Manual A Con
© 2010 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 4
Heat Auto/ Manual No 2 Heat/ 2 Cool Back-lit Digital Fahrenheit or Celsius Temps/ Service Filter Hard-wired & UV G3271C Gas Heat Electric Heat Electric Cool Auto/ Manual 7-day 3 Heat/ 2 Cool Back-lit Digital Fahrenheit or Celsius Outdoor Temps/ Service Filter & UV Hard-wired G3272C Gas Heat Electric Heat Electric Cool Auto/ Manual 7-day 3 Heat/ 2 Cool Back-lit Digital Fahrenheit or Celsius Outdoor Temps/ Service Filter & UV Hard-wired CommeRCial theRmostats anD unit matChes Model A/C Heat Pumps
TSTAT G3272C 7-Day pRogRammable with smaRt fan • 3-stageheat/2-stagecool• Upto3occupiedperiodsperday• Outdoortemperaturedisplay• LightActivated• ProgrammableOutput• EconomizerControl• Canaveraagewithupto8remotesensors• Reheat-Capable• Pre-occupancyfanpurge• AcceptsHumidityModule• DryContactInput• HolidayMode• EnergySaver/EnergyWatchSS GTS-C6/09 Supersedes 7/08 Digital Room theRmostats foR CommeRCial appliCations featuRes Standard Features • Controlsupto3configurableoutputsformaximumflexibility•
+fan EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140361B* / AR* F374316B* Outdoor Ambient Temperature65 75 85 95 105 115 Entering Indoor Wet Bulb TemperatureIDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1090 MBh 30.7 31.9 34.9 - 30.0 31.1 34.1 - 29.3 30.4 33.3 - 28.6 29.6 32.5 - 27.2 28.2 30.8 - 25.2 26.1 28.6 - S/ T 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48 - Delta T 19 16 12 - 19 16 12
Overcurrent Protection 60 60 70 Min / Max Volts 197/253 197/253 197/253 Electrical Conduit Size /" or %" /" or %" /" or %" SHip WEiGHT (lbs) 254 254 315 1 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes 2 May use fuses or HACR type Circuit Breakers of the same size as noted Notes • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply 1V' to 1%" or 1%" to
+fan) EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: GSH140301A* / CA*F3636B6A* +TXV / MBR1200**-1 Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions Outdoor Ambient Temperature65 75 85 95 105 115 Entering Indoor Wet Bulb TemperatureIDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1214 MBh 27.4 28.4 31.2 - 26.8 27.8 30.4 - 26.2 27.1 29.7 - 25.5 26.5 29.0 - 24.2 25.1 27.5 - 22.5 23.3 25.5 - S/ T 0.80 0.67 0.46 - 0.83 0.69 0.48 -
◊ 5151 San Felipe, Suite 500 ◊ Houston, TX 77056 RP-526A April 2009 Important Information Index Functional Parts List ................................................................................................... 3 Illustration and Parts ................................................................................................... 4 - 13 Views shown are for parts illustrations only, not servicing procedures. This system uses R410A refrigerant. If sealed system work is required, u
MBVC BLOWER SPECIFICATIONS H (3) KNOCKOUTS1.125 1.375 1.750 .875 KNOCKOUT (2 PLACES) 6 1/2 5 5 1/8 3 1/4 D W MBVC1200/1600/2000 MODEL Physical Information Dimensions, inches (mm) Shipping Weight lbs.(kg) Blower Wheel (D x W) Blower Motor (HP) MCA1 MOP1 W H D MBVC1200 10X8 1/2 4.3 15 17. (445) 26 (660) 21 (533) 72 (32.6) MBVC1600 10X8 3/4 6.3 15 21 (533) 30 (762) 21 (533) 82 (37.2) MBVC2000 11X10 3/4 5.8 15 24. (622) 30 (762) 21 (533) 94 (42.6) Minimum Circuit Ampacity (MCA) and Maximum Overcurre