This compact package provides the connection integrity of flanged body globe valves while being significantly lighter and easier to install. SCOPE OF MANUAL This instruction manual includes installation, maintenance, and parts information for the 51000 series control valve and type 16 actuator. No person may install operate or maintain a 51000 series control valve without first being fully trained and qualified in valve, actuator and accessory installation, operation and maintenance, and careful
Description The Type 99 gas regulators provide a broad capacity for controlled pressure ranges and capacities in a wide variety of distribution, industrial, and commercial applications. A Type 99 regulator has a Type 61L (low pressure), Type 61H (high pressure), or a Type 61HP (extra high pressure) pilot integrally mounted to the actuator casing as shown in Figure 1. The Type 99 regulator can handle up to 1000 psig (69,0 bar) inlet pressures (the 1000 psig (69,0 bar) regulator requires a Type 13
• Wahrend der Installation und der Wartung der Gerate sichere Arbeitsbedingungen entsprechend dem Medium und dem Prozess herrschen. • Die Konstruktionsmaterialien sind fur die Anwendung geeignet. Siehe auch Tabelle 1 • Die Druck- und Temperaturgrenzen fur dieses Produkt nicht uberschritten werden, wenn notig unterEinsatz geeigneter zusatzlicher Sicherheitseinrichtungen. Siehe auch Tabelle 3 • An allen zutreffenden Stellen nur von Mobrey Measurement gelieferte Befestigungsschrauben eingesetzt und
Improper use of this device in some applications may result in damage or injury. The user is urged to keep this book filed in a convenient location for future reference. These instructions may not cover all details or variations in equipment or cover every possible situation to be met in connection with installation, operation or maintenance. Should problems arise that are not covered sufficiently in the text, the purchaser is advised to contact Bristol for further information. EQUIPMENT APPLICA
A 1/4 inch NPT vent is provided on the pressure regulator body for this purpose. The vent location is shown in Figure 2-3. When air is used as the pressure source, the vent fitting may be allowed to bleed into the atmosphere. If fuel gas or other hazardous type gases are used as the pressure source for a Remote Set Regulator, the VENT port must be piped to a safe location. ** Warning ** Covers of Remote Set Regulators operating in hazardous areas should not be removed. If servicing is required,
However, with the growing popularity of Bristol® ControlWave®, from Emerson Process Management, the latest generation hybrid PLC/RTU products, customers have expressed interest in an inexpensive migration path to allow them to realize all of the benefits of the new ControlWave technology without replacing their entire SCADA system. The new CPU products, named CW_10, CW_30, CW_35 and CW_31 (generically CW_XX), are intended to offer a cost-effective upgrade path to the ControlWave architecture for
For most applications, the ACCOL Translator will reduce the conversion effort by up to 80% vs. rewriting the program. To properly take advantage of the ACCOL Translator, one must know ACCOL, ControlWave Designer, understand the ACCOL application and have access to the ACCOL source file. Once the application is translated, it typically requires some degree of editing, depending on the complexity of the program, and thorough testing prior to deployment on-site. Emerson Process Management can provi