Log:

FMI Becton 7 mk3

Téléchargements : 5 Taille : 525 kb    Fabricant : FMI  
Catégorie : Cheminées

Ensure the rear matrix is pushed back against the location bar. (Fig 4b) Fig 4b Step 3 Becton 7 only. Locate 2 off end coals each side of the base matrix. (See underside of coals for hand identification) (Fig 4c). Fig 4c Becton Bunny & Becton 7 mk3 Gas stoves OPERATING INSTRUCTIONS LIGHTING & CONTROLLING THE FIRE Under no circumstance must the fire be operated if the glass is cracked or broken. Open the gas control access door situated at the bottom of the appliance. Always use the control door

FMI Becton Bunny

Téléchargements : 17 Taille : 525 kb    Fabricant : FMI  
Catégorie : Cheminées

See "SAFETY NOTICES" ref coal set page 4. Ensure the appliance is cold. Step 1 Isolate the gas supply to the fire using the gas cock supplied at installation. Step 2 Open the fire door, (Held closed using a magnet). Step 3 Remove the glass frame and the glass/ gasket assembly. Step 4 Carefully remove and clean the coal set of any soot deposits using a soft brush. Step 5 Carefully remove and clean the firebox linings. Where necessary. Step 6 Inspect the chimney and flue terminal ensuring they are

FMI BOOKMAN EMQ-640

Téléchargements : 0 Taille : 135 kb    Fabricant : FMI  
Catégorie : Radiateurs à gaz

BOOKMAN. EXPANDABLE ELECTRONIC BOOK Hutchinson Popular Encyclopedia USER’S GUIDE EMQ-640 License Agreement READ THIS LICENSE AGREEMENT BEFORE USING ANY BOOKMAN ELECTRONIC BOOK. YOUR USE OF THE BOOKMAN ELECTRONIC BOOK DEEMS THAT YOU ACCEPT THE TERMS OF THIS LICENSE. IF YOU DO NOT AGREE WITH THESE TERMS, YOU MAY RETURN THIS PACKAGE WITH PURCHASE RECEIPT TO THE DEALER FROM WHICH YOU PURCHASED THE BOOKMAN ELECTRONIC BOOK AND YOUR PURCHASE PRICE WILL BE REFUNDED. BOOKMAN ELECTRONIC BOOK means the sof

FMI FMH26TN

Téléchargements : 1 Taille : 732 kb    Fabricant : FMI  
Catégorie : Cheminées

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be per- formed by a qualified installe

FMI FMH26TP

Téléchargements : 14 Taille : 753 kb    Fabricant : FMI  
Catégorie : Cheminées

Use a No. 16 AWG cord for lengths less than 50 feet. Attaching Wood Base to Solid Floor For attaching base to solid floors (concrete or masonry) Note:Floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace. 1. Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep. 2. Fold floor anchor as shown in Figure 22. 3. Insert floor anchor (wings first) into hole. Tap anchor flush to floor. 4

FMI FVF18P

Téléchargements : 0 Taille : 407 kb    Fabricant : FMI  
Catégorie : Radiateurs à gaz

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer,

FMI FVF18PW

Téléchargements : 0 Taille : 410 kb    Fabricant : FMI  
Catégorie : Radiateurs à gaz

Combustible Material Noncombustible Material Hearth Combustible Material5” Min. Underside of Mantel Shelf All minimum distances are in inches Log Set 24"/30" Models 18" Model Top of Fireplace Underside of Mantel Shelf All minimum distances are in inches Log Sets All Models Top of Fireplace Opening Continued 105194 9 FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE/LP GAS LOG HEATER INSTALLATION Continued INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note:When used as a vented heate

FMI FVF24P

Téléchargements : 0 Taille : 407 kb    Fabricant : FMI  
Catégorie : Radiateurs à gaz

If damaged, operate heater with flue damper closed. 8. If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater. 9. This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, sli

FMI FVF24PW

Téléchargements : 0 Taille : 410 kb    Fabricant : FMI  
Catégorie : Radiateurs à gaz

Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet. CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur. Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Loca

FMI FVF30P

Téléchargements : 1 Taille : 407 kb    Fabricant : FMI  
Catégorie : Radiateurs à gaz

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot. It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Place one-piece log set on grate to fit as illustrated in Figur