Log:

United States Stove 1200Q

Téléchargements : 1 Taille : 299 kb    Fabricant : United States Stove  
Catégorie : électrique

Future Reference DO NOT USE THIS FURNACE IN A MOBILE HOME OR TRAILER COMPANYUNITEDSTATESSTOVECSSU UNITED STATES STOVE COMPANY WARNOCK HERSEY 227 Industrial Park Road P.O.Box 151 South Pittsburg, TN 37380 (423) 837-2100 R 851282A 4/99 CONGRATULATIONS! CONGRATULATIONS! You've purchased one of America's Finest Wood Burning Furnaces. By heating with wood you're helping to CONSERVE AMERICA'S ENERGY! Wood is our Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least

United States Stove 1261

Téléchargements : 10 Taille : 160 kb    Fabricant : United States Stove  
Catégorie : électrique

When installing your heater, use care in handling. Clean with soap and warm water when heater is not hot. DO NOT use any acids or scouring soap, as these wear and dull the finish. PAINT DISCOLORATION WILL OCCUR IF THE HEATER IS OVERFIRED. FOLLOW OPERATING INSTRUCTIONS CAREFULLY. 13. All persons, especially children, should be alerted to hazards from high surface temperatures and kept away while in operation. Small children should not be left unsupervised when in the room with the heater. 14. Kee

United States Stove 1303

Téléchargements : 5 Taille : 138 kb    Fabricant : United States Stove  
Catégorie : électrique

See Wiring Diagram (Fig. 12 or Fig. 13). Remove the cover from electrical junction box and connect power supply wires to wires designated, using wire nuts. The power cord supplied may be used for installation, if permitted by local codes and regulations. If the power cord supplied cannot be used, the power supply wiring must be 90 degrees centigrade in a metal cable and should be completed by a qualified installer complying with NFPA Standard No. 70 and local codes. g) Optional Plenum Fan Contro

United States Stove 1321

Téléchargements : 0 Taille : 122 kb    Fabricant : United States Stove  
Catégorie : Air

Be sure to use a masonry chimney that it is safely constructed and in good repair. Have the chimney inspected by the Fire Department or an inspector. 6. Inspect chimney connector and chimney before and frequently during the heating season for any deposit of creosote or soot which must be removed (See Chimney Maintenance, page 18). 7. Provide air for combustion into the room where the furnace is located. If the intake is not in the same room, air must have free access to the room. 8. CAST IRON PA

United States Stove 1357M

Téléchargements : 0 Taille : 3 mb    Fabricant : United States Stove  
Catégorie : électrique

5. A listed factory-built wall pass-through system may be purchased and installed according to the instructions packaged with it to provide a safe method of passing the chimney connector through a combustible wall for connection to a masonry chimney. Additional requirements pertaining to Figure 8 and the above wall pass-through systems: 1. Insulation material used as part of wall pass-through system shall be of noncombustible material and shall have a thermal conductivity of 1.0 Btu • in./ft.. •

United States Stove 1500

Téléchargements : 0 Taille : 730 kb    Fabricant : United States Stove  
Catégorie : électrique

2 & 3) 3.Place the furnace on a noncombustible floor. 4.Check figures 2 and 3. Be sure you have the clearances shown from the furnace and the connector pipe to combustible surfaces. If you have a solid brick or stone wall behind your furnace, you can place the furnace as close as you wish to the wall. If the wall is only faced with brick or stone, treat it as a combustible wall. 12" 9" 48" 18" CENTRAL FURNACE 6" CHIMNEY Figure 2 18" 18" 6" SOLID DAMPER 6" BAROMETRIC DRAFT REGULATOR (OPTIONAL) NO

United States Stove 1537G

Téléchargements : 0 Taille : 188 kb    Fabricant : United States Stove  
Catégorie : électrique

2. The installation is to be done in compliance with National Fire Protection Association installation standards: No. 89M, 90B, 211, 70 (National Electrical Code) and Uniform Mechanical Code 913, 6-4, in the states where applicable. (Their code offers connecting smoke pipe connectors into chimney with other fuel burning appliances.) 3. Rooms large in comparison with size of the appliance: a) Wood or Coal Burning Furnace needs air for combustion and circulation to house. b) Provision must be made

United States Stove 1537M

Téléchargements : 0 Taille : 264 kb    Fabricant : United States Stove  
Catégorie : électrique

FURNACE.FURNACE.FURNACE.FURNACE.FURNACE. • FOR INSTALLATION AS A CENTRAL FURNACE • FOR INSTALLATION AS A CENTRAL FURNACE• FOR INSTALLATION AS A CENTRAL FURNACE• FOR INSTALLATION AS A CENTRAL FURNACE• FOR INSTALLATION AS A CENTRAL FURNACE• FOR INSTALLATION AS A CENTRAL FURNACE • THE 1537M HOTBLAST FURNACE HAS BEEN APPROVED FOR U.S. INSTALLATIONS • THE 1537M HOTBLAST FURNACE HAS BEEN APPROVED FOR U.S. INSTALLATIONS• THE 1537M HOTBLAST FURNACE HAS BEEN APPROVED FOR U.S. INSTALLATIONS• THE 1537M HOT

United States Stove 1537Q

Téléchargements : 0 Taille : 182 kb    Fabricant : United States Stove  
Catégorie : électrique

7 chimney connection FIG. 4 6" SOLID DAMPER 6" BAROMETRIC DRAFT REGULATOR (OPTIONAL) THIMBLE 6" ELBOW 6" CHIMNEY CONNECTOR 6" ELBOW NON-COMBUSTIBLE WALL MASONRY CHIMNEY Before using an existing masonry chimney, clean the chimney and inspect the flue liner to be sure it is safe to use. Make repairs before attaching the furnace. See Page 4, item 5. Look at Fig. 4. The connector pipe and fittings you will need to connect directly to a masonry chimney are shown. The chimney connection should be as s

United States Stove 1557M

Téléchargements : 5 Taille : 3 mb    Fabricant : United States Stove  
Catégorie : électrique

UFB908 Universal Filter Box When installing ANYwarm air furnace, proper installation is the key and required for getting the most efficiency and longest life out of your unit. Failure to install your furnace as outlined from the manufacturer, often will result in inadequate heating and problems associated with drafting. U. S. Stove Co. offers the UFB908, a universal filter box that mounts to the rear of the unit that your return air duct work will attach to. It uses a standard 16 x 20 x 1 filter





catégories