Log:

Zephyr Adjustable Depth Liners AK088xAS

Téléchargements : 3 Taille : 121 kb    Fabricant : Zephyr  
Catégorie : Ventilateurs

For the liner installation, only the bottom of the custom hood is needed. Do not finalize the entire custom hood yet, because an opening is needed for the power pack. 0) c o (0 Û- Liner Model Power Pack Model Custom Hood Exterior Width *Inside Width (A) *Inside Depth (B) Without Backboard **With Backboard AK0800AS AK8000AS and AK8100AS 30 inches 28 1/2” 17 1/2” - 20 1/2” 17 1/8” - 20 1/8” AK0836AS 36 inches 34 1/2” AK0806AS AK8200AS 36 inches 34 1/2” 20 1/2” - 23 1/2” 20 1/8” -

Zephyr AHZ-M90ABX

Téléchargements : 2 Taille : 2 mb    Fabricant : Zephyr  
Catégorie : Ventilateurs

However, if required, it is possible to have the exhaust air discharged from the top. This can be accomplished by carrying out the steps indicated in the following paragraphs; upon reaching step 5, the blower plate must be rotated and installed in the opposite direction. The following instructions are for preparing the hood for use with an external or in-line blowers models CBE-1000 or PBN-1000A. CAUTION: To reduce the risk of fi re and electric shock, install this rangehood only with remote blo

Zephyr AHZ-M90ARX

Téléchargements : 5 Taille : 2 mb    Fabricant : Zephyr  
Catégorie : Ventilateurs

E. Watch constantly the fried food in order to avoid the cooking oil fl ares up. F. before performing any mainteinance operation, disconnect the hood from the electrical service. The manufacturers will not to accept any responsability for eventual damages, because of failure to observe the above instructions. - 6 - List of Materials Control Electrical Junction Box Glass Glass Light Bulbs Decorative Mesh Filters Range Hood Body Top Cover TYPE DESCRIPTION N° A M4 1 + 1 B 1/8" x 1/4" 12 C 1/8" x 2/

Zephyr AHZ-M90AWX

Téléchargements : 3 Taille : 2 mb    Fabricant : Zephyr  
Catégorie : Ventilateurs

See Fig. 9 Note2: Check local codes to determine minimum wire gauge. See manual included with external and in-line blower for instructions on installing the blower. Installation - External & In-Line Blower Preparation - 15 - Installation - Ducting Options WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal duct

Zephyr AK11005

Téléchargements : 0 Taille : 658 kb    Fabricant : Zephyr  
Catégorie : Ventilateurs

g. NEVER place a switch where it can be reached from a tub or shower. h. Make sure the power is off before installing, wiring or maintenancing. Important 3 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. NOT FOR USE OVER AN OUTDOOR GRILL. CAUTION To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. For indoor use only. Do not use over cooking equipment greater than 60,000 BTU/hr. Th

Zephyr AK11245

Téléchargements : 14 Taille : 658 kb    Fabricant : Zephyr  
Catégorie : Ventilateurs

Select preferred duct location (vertical or horizontal) if ducting out of kitchen. Refer to page 7 for details. 2. Begin installation by removing the fi lters (if installed) and side spacer panels (36” models only). (Fig 2) 3. Reinforce cabinet with 1”x2” wood strips if additional strengthening is required or if cabinets are framed. 4. Temporarily position the range hood in the desired mounting location. Measure and mark the mounting holes, duct and electrical locations with a pencil. 5. Drill/c

Zephyr AK11365

Téléchargements : 5 Taille : 658 kb    Fabricant : Zephyr  
Catégorie : Ventilateurs

If you are outside our service area, additional charges may apply for shipping costs for warranty repair at our designated service locations and for the travel cost to have a service technician come to your home to repair, remove or reinstall the Products. After the first year from the date of your original purchase, you are also responsible for all labor costs associated with this warranty. Limitations of Warranty. OUR OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE YOUR SOLE AND EXCLU

Zephyr AK7500ASX

Téléchargements : 4 Taille : 393 kb    Fabricant : Zephyr  
Catégorie : Ventilateurs

Place cap over threaded end of remote blower wiring and secure by turning clockwise. 1. Place 10” round adapter on top of hood and 2. Install threaded end of remote blower wiring secure with (4) M4x8 screws. Connect 10” through external blower wiring knock out round duct work to 10” round adapter. located inside the hood. CBE-1000 / PBN-1000A: WIRING DIAGRAM 4. Connect 6 pin male connector from remote blower wiring to 6 pin female connector on control board wire inside hood. Secure green ground

Zephyr AK7536ASX

Téléchargements : 6 Taille : 393 kb    Fabricant : Zephyr  
Catégorie : Ventilateurs

4 INSTALLATION Ducting Calculation Sheet....................................... 5 Mounting Height & Clearance................................ 6 Ducting Options........................................................... 7 Specifi cations ............................................................... 8 Electrical ......................................................................... 9 Mounting the Range Hood...................................... 10 CBIxxxB and PBI-1100A Internal Blowers.......

Zephyr AK7548ASX

Téléchargements : 2 Taille : 393 kb    Fabricant : Zephyr  
Catégorie : Ventilateurs

If available, also refer range manufacturer’s height clearance requirements and recommended hood mounting height above range. Vertical Ducting: 6” round minimum (CBI-xxxB blower) 10” round minimum (PBI-1100A and remote blowers) Horizontal Ducting: 3-1/4”x10” minimum (CBI-xxxB blower) No horizontal option available for PBI-1100A or remote blower DAMAGE-SHIPMENT / INSTALLATION: • Please fully inspect unit for damage before installation. • If the unit is damaged in shipment, return the unit to the





catégories